1. Calibration of empty forks with operator on platform lifted just above
the ground
To initiate calibration press the
“M”
button (use a paper clip) and hold it down for approx. 5
seconds.
After approximately five-seconds the Mode LED
display digit will change from
Mode 8
to
Mode 0
.
System is ready for automatic zeroing
When LED display is showing
Mode 0
lift the empty
forks with operator on the platform
just above the
ground.
The LED display showing
Mode 0
will go blank and
after few seconds display will show
Mode 1.
Automatic zeroing is done
2. Calibration of loaded forks with operator lifted to the highest operational
forks height
*At this point drive your vehicle into the skid load with known weight
and lift the load to the
highest operational forks height.
With LED display showing
Mode 1
start entering the known calibration load
weight value by using
Arrow Up
button (increments from 0 to 9) wrap
around. Start with Digit 1, least significant digit (in our case input number
“3”
) and press momentarily button
“M”
to advance to next Digit 2. Input number
“3”
and press momentarily button
“M”
to advance to next Digit
3. Keep doing the same until
00033
is entered into the system.
Make sure that digits 3,4 and 5 are “0”.
(The calibrated % value has only two digits)
Example: (In our calculation example we will use 1000 pounds as known calibration load weight)
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
Paper Clip