background image

!

Note:                                                                                                                                 

To initiate a load weighing cycle, loaded forks must be lowered to the ground.

 

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7 

www.skidweigh.com

   

Содержание ED3-AT SkidWeigh Plus

Страница 1: ... Plus Series RF Base Station Lift Truck On board Check Weighing With Bar Code Reader Version Custom Software ED4 Wilson Logistics Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com ...

Страница 2: ...d hydraulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected directly ...

Страница 3: ...the hydraulic lift circuit must be pressure free There are two ways to do that 1 Place the forks on the ground in their lowest position and make the hydraulic system pressure free by tilting the mast forward The chain s should be slack 2 Lift the forks and position them on the top of a supporting fixture Start lowering the lifting cylinder into its lowest position Be sure that chain s are slack Ma...

Страница 4: ...the pressure transducer cable White Wire connect to WHITE wire of the pressure transducer cable Pressure transducer cable White Wire signal 0 to 2 5 V Black Wire signal negative Red Wire power supply 11 V DC Power short circuit protection All SkidWeigh systems are internally short circuit protected with resettable fuse There is no need to install external inline fuse in orange wire connected to th...

Страница 5: ...andom load weight Example 455 If the above test is valid than the system electrical connections are done right The next procedure will be to calibrate the SkidWeigh weighing function and perhaps set the right time and date if current value is wrong Pressure transducer test procedure The ED3 SkidWeigh Plus system has provision that you can test the operation and working of the pressure transducer i...

Страница 6: ...ic software algorithm to obtain load weight accuracy within 1 of vehicle maximum lifting capacity Date Time Set Up In the event that date and time is not right you can correct when you press F key and hold it for the moment until LCD display shows ENTER FUNCTION Press number 3 and display will be in date time change mode Use left and right arrow key bottom left side of the keypad to change the val...

Страница 7: ...round There should be no hydraulic pressure in lift hydraulic circuit Turn ignition switch to on position electric lift trucks and start the engine on combustion powered lift trucks LCD display will show software version and serial number for the moment and date and time will be displayed Calibration To initiate system calibration and LCD display must be showing date time Press and hold F key unti...

Страница 8: ... loaded forks just above the ground After few seconds the calibrated load weight value of of 2000 will be stored in the system memory and the LCD display will go back to showing date and time Calibration of the ED3 ED4 AT system weighing function is finished LCD Display CALIBRATION 1 WEIGHT LCD Display CALIBRATION 1 WEIGHT 2000 LCD Display CALIBRATION 1 LIFT LOAD LCD Display CALIBRATION 1 LOWER FO...

Страница 9: ... Insert the forks into the pallet or under the product to be weighed Lower the forks to the ground LCD display must show date and time Use Motorola bar code scanner Upper LCD row will show current 12 digit product identification Activate lift control valve and lift loaded forks just above the ground LCD will display PLEASE WAIT and after few seconds a load weight will be shown in addition to the b...

Страница 10: ... Note To initiate a load weighing cycle loaded forks must be lowered to the ground Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com ...

Страница 11: ...Station Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Power supply and USB port Wilson Logistics Use Clock More icon to get into managing data ...

Страница 12: ...sual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Wilson Logistics Application Use SAVED DATA input only in order to manage data Wilson Logistics Managing data options ...

Страница 13: ... Base Station Mobile USB Recording As of March 19 2015 Ottawa System Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com ...

Страница 14: ... USB Data Download From Mobile Unit Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com ...

Страница 15: ...umber 6 LCD will show saving to USB Erase SDRAM on mobile unit N Default is N Press left or right arrow to change to Y Press Enter key to confirm Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com ...

Отзывы: