- 1 -
Installation
Hardware Installation
Please verify that your product package contains
all the accessories listed in the foregoing
Package Contents. Depending on the user’s
application, an Ethernet cable may be needed.
The Ethernet cable should meet the specs of UTP
Category 5 and not exceed 100 meters in length.
Connect the power adapter jack to the
Network Camera before plugging in to the power
socket. This will reduce the risk of accidental
electric shock.
Upon powering up, the device runs through a self-test procedure and the front LEDs will blink
between green and red for a few times. If self-test passes, the LEDs will shut off and the Network
Camera will be on stand-by and ready for software installation. If self-test fails the red LED will
blink several times. Refer to Appendix A for troubleshooting.
To install in Ethernet
Make sure the Ethernet is firmly connected to a switch hub. After attaching the Ethernet cable
plug in the power adapter. If the LED turns out to be steady green after self-test, go to next
paragraph “Software Installation”.
1 DI+
INPUT (Max. 50mA, 12VDC)
2 DI-
INPUT (Initial state of DI is low)
3 SW_COMMON
OUTPUT (open from SW_OPEN at initial state)
(close with SW_OPEN when set DO to ON)
4 SW_NOPEN OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC)