background image

 

 

 
 
 
 
 

 

 

 

- 1 - 

 

 

 

 

Installation 

Hardware Installation 

Please verify that your product package contains 

all  the  accessories  listed  in  the  foregoing 

Package  Contents.    Depending  on  the  user’s 

application, an  Ethernet cable may be needed. 

The Ethernet cable should meet the specs of UTP 

Category 5 and not exceed 100 meters in length. 

 

  Connect  the  power  adapter  jack  to  the 

Network Camera before plugging in to the power 

socket.  This  will  reduce  the  risk  of  accidental 

electric shock. 

 

Upon powering up, the device runs through a self-test procedure and the front LEDs will blink 

between green and red for a few times. If self-test passes, the LEDs will shut off and the Network 

Camera will be on stand-by and ready for software installation. If self-test fails the red LED will 

blink several times. Refer to Appendix A for troubleshooting. 

 

To install in Ethernet 

Make sure the Ethernet is firmly connected to a switch hub. After attaching the Ethernet cable 

plug in the power adapter. If the LED turns out to be steady green after self-test, go to next 

paragraph “Software Installation”.  

 

1   DI+  

 

INPUT (Max. 50mA, 12VDC) 

2   DI-   

 

INPUT (Initial state of DI is low) 

3   SW_COMMON   

OUTPUT (open from SW_OPEN at initial state) 

   

 

 

 

(close with SW_OPEN when set DO to ON) 

4   SW_NOPEN      OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC) 

 

 

Содержание PTZ-3300-01

Страница 1: ...NetworkCam PTZ 3300 01 User s Manual ...

Страница 2: ... 1 Package Contents Network Camera Power adapter A V Cable Remote Controller Camera stand ...

Страница 3: ... the front LEDs will blink between green and red for a few times If self test passes the LEDs will shut off and the Network Camera will be on stand by and ready for software installation If self test fails the red LED will blink several times Refer to Appendix A for troubleshooting To install in Ethernet Make sure the Ethernet is firmly connected to a switch hub After attaching the Ethernet cable ...

Страница 4: ...ent Unauthorized Access The default Administrator s password is blank and the Network Camera initially will not ask for any password The Administrator should immediately implement a new password as a matter of prudent security practice Once the Administrator s password is saved the Network Camera will ask for the user s name and password before each access The Administrator can set up a maximum of...

Страница 5: ...Any hardware failure Other patterns Reset and Restore At the left side of the camera there is a button hidden in the pinhole as shown in the picture It is used to reset the system or restore the factory default settings Sometimes resetting the system sets the system back to normal state If the system problems remain after reset restore the factory settings and install again RESET Poke the wrench t...

Страница 6: ...supported MPEG4 SP MJPEG Resolution Up to 30 25 frames at 176x120 or 176x144 Up to 30 25 frames at 352x240 or 352x288 Up to 15 12 frames at 704x480 or 704x576 Camera specification 1 4 inch color CCD sensor Typical 1 5 Lux F1 8 Low lux mode 0 05 Lux F1 8 AGC AWB Electronic shutter 1 60 1 50 to 1 120 000 sec Pixel Numbers NTSC 542 H x496 V or PAL 542 H x586 V Lens Focal length 4 2 42mm Aperture F1 8...

Отзывы: