Ivation IVADGOZHEPA Скачать руководство пользователя страница 7

7

To clean each plate:

1.  Turn the unit OFF via the power button and the power switch at the rear. Wait for the fan to stop spinning and then 
 

unplug from the outlet.

2.  Remove all the filters preceding the plates from the rear of the unit by unscrewing the black knob that holds the 
 

rear cover in place. 

3.  Pull each ozone plate gently, but firmly, toward you and out of the unit. 

4.  Wash the plate carefully, with warm water applied to both sides of the 
 

plate to rinse it well. If you prefer to use clear ammonia, you can do a 

 

mixture of warm water and ammonia (a 50/50 mixture is best) and 

 

allow the plate to soak in the mixture for about 10-15 minutes. 

5.  Gently scrub with a stiff brush if you notice any deposits not coming off 
 

with just the water rinse. Be careful not to drop the plate or scrub off 

 the 

silicon.

6.  Clean both the metal screen and the ceramic tile of the plate.

7.  Rinse the plate with water and allow it to dry completely before replacing 
 

it. If you have one available, you may use a hair dryer to gently dry 

 the 

plate. 

8.  Replace the ceramic plate, making sure it is fully inserted and seated 
 securely 

in 

place. 

9.  Reassemble the unit and plug it into a properly grounded electrical outlet and turn it on. 

To clean the needlepoint ionizer:

1.  Turn the unit OFF via the power button and the power switch at the rear. Wait for the fan to stop spinning and then 
 

unplug from the outlet.

2.  Remove the fan grill cover from the front of the device by pulling it straight toward you. You may need to use your 
 

fingernails or a flat object to get between the grill cover and the cabinet.

3.  You can locate the needle-point ionizer easily by looking in front of the fan for two pieces of metallic wire. 

4.  Take a Q-tip or cotton swab dipped in isopropyl alcohol and use those to gently clean away any dust that may have 
 

accumulated on the needle points. 

5.  While you have the fan grill cover off the unit, you may use a damp cloth to gently wipe clean the fan blade, and 
 

rinse the fan grill cover with warm water. Make sure the grill cover is completely dry before reassembling the unit.

1

2

3

Содержание IVADGOZHEPA

Страница 1: ...ranty Please read all directions before using the product and retain this guide for reference This product is intended for household use only It is not intended for commercial use This product is covered by a limited one year warranty Coverage is subject to limits and exclusions See warranty for details TABLE OF CONTENTS 2 SAFETY PRECAUTIONS 2 PACKAGE CONTENTS 3 PRODUCT OVERVIEW 4 HOW DOES IT WORK...

Страница 2: ...trongly recommend that you only operate the unit for the shortest recommended time for your room size Do not attempt to disassemble this unit There are no user serviceable parts inside the unit To avoid electric shock plug the unit into a grounded electrical outlet Make sure the unit is placed on a flat even surface in a well ventilated area Do not block the fan vent or the back of the unit Do not ...

Страница 3: ...n Grill Removable fan grill Wash with warm water to clean and allow to dry completely before replacing Always unplug unit before removing grill E Plate Receiver Slot Allows for the insertion and removal of the ceramic O3 plates for cleaning F Power Cord 120 V grounded cord do NOT bypass ground wire cord G TiO2 Photo catalytic Filter Do not wash Clean this filter with compressed air H Ceramic Plate ...

Страница 4: ...air The electrical current transforms an ordinary O2 molecule into an O3 molecule If you ve taken a walk after a thunderstorm and experienced the fresh clean smell in the air you ve experienced the after effects of ozone at work in the environment The Ivation Digital Ozone Air Purifier with HEPA Filter creates O3 via a special process that utilizes an electrical current and the oxygen in the room T...

Страница 5: ... position Once the fan stops spinning your ozone air purifier is ready to be programmed 2 Use the Fan or Fan buttons to set your desired fan speed Your chosen fan setting will be illuminated on the LCD panel display 3 Use the Ozone or Ozone buttons to set your desired ozone output level The level you choose will be illuminated on the LCD panel display There are four levels I II III and IV NOTE If t...

Страница 6: ...tor on the LCD display screen will start blinking 5 While the Ozone Timer OFF light is blinking use the Fan or Fan buttons to set the hour you want the purifier to turn off 6 Use the Ozone or Ozone buttons to adjust the minutes of the time when you want the purifier to turn on Once the Unit and Ozone timers have both been set press the Unit Timer button and then the Ozone Timer button to finalize the...

Страница 7: ...replacing it If you have one available you may use a hair dryer to gently dry the plate 8 Replace the ceramic plate making sure it is fully inserted and seated securely in place 9 Reassemble the unit and plug it into a properly grounded electrical outlet and turn it on To clean the needlepoint ionizer 1 Turn the unit OFF via the power button and the power switch at the rear Wait for the fan to sto...

Страница 8: ...xt to the power cord socket Remove the old fuse and replace with the new one One spare fuse is included the unit itself The fuse type is 1A 250V 1 25 31 75mm 6 Make sure that the ozone air purifier is properly plugged into a grounded outlet to avoid the potential for electrical shock and also to ensure proper functionality 7 Check the plate alignments to make sure each ceramic plate has been insert...

Страница 9: ...s company names and logos are trademarks of their respective owners used merely to identify their respective products and are not meant to connote any sponsorship endorsement or approval Distributed by C A Marketing Inc 114 Tived Lane East Edison NJ 08837 Made in China 2019 C A IP Holdings LLC All Rights Reserved QUESTIONS OR PROBLEMS CONTACT US info myivation com 1 866 849 3049 ...

Отзывы: