background image

12

Up

8x 01 04 0A 02 FF

Down

8x 01 04 0A 03 FF

Direct

8x 01 04 4A 00 00 0p 0q
FF

pq

Shutter Position

CAM_Iris

Reset

8x 01 04 0B 00 FF

Iris Setting

Up

8x 01 04 0B 02 FF

Down

8x 01 04 0B 03 FF

Direct

8x 01 04 4B 00 00 0p 0q
FF

pq

Iris Position

CAM_Gain

Reset

8x 01 04 0C 00 FF

Gain Setting

Up

8x 01 04 0C 02 FF

Down

8x 01 04 0C 03 FF

Direct

8x 01 04 4C 00 00 0p 0q
FF

pq

Gain Position

CAM_Bright

Reset

8x 01 04 0D 00 FF

Bright Setting

Up

8x 01 04 0D 02 FF

Down

8x 01 04 0D 03 FF

Direct

8x 01 04 4D 00 00 0p 0q
FF

pq

Bright Position

CAM_ExpComp

On

8x 01 04 3E 02 FF

Exposure

Compensation

ON/OFF

Off

8x 01 04 3E 03 FF

Reset

8x 01 04 0E 00 FF

Exposure

Compensation

Amount Setting

Up

8x 01 04 0E 02 FF

Down

8x 01 04 0E 03 FF

Direct

8x 01 04 4E 00 00 0p 0q
FF

pq

ExpComp Position

CAM_Backlight

On

8x 01 04 33 02 FF

Back

Light

Compensation

ON/OFF

Off

8x 01 04 33 03 FF

CAM_Aperture

Reset

8x 01 04 02 00 FF

Apeture Contro;

Up

8x 01 04 02 02 FF

Down

8x 01 04 02 03 FF

Direct

8x 01 04 42 00 00 0p 0q FF

pq

Aperture Gain

CAM_LR_Reverse

On

8x 01 04 52 03 FF

Mirror Image ON/OFF

Off

8x 01 04 61 02 FF

CAM_Freeze

On

8x 01 04 62 02 FF

Still Image ON/OFF

Off

8x 01 04 62 03 FF

Содержание 23X Block Camera

Страница 1: ...23X 23X 23X 23X Block Block Block Block Camera Camera Camera Camera User User User User s s s s Manual Manual Manual Manual Version Version Version Version 1 0 1 0 1 0 1 0 ...

Страница 2: ...f Contents Contents Contents Contents Welcome 3 1 General Introduction 5 1 1 Overview 5 1 2 Functions 5 1 3 Specifications 6 2 Framework 8 2 1 Dimension 8 2 2 Port 9 3 Command List 11 Appendix Toxic or Hazardous Materials or Elements 14 ...

Страница 3: ...ur block camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user s manual well for future reference ...

Страница 4: ...Qualified engineers engineers engineers engineers needed needed needed needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 5 5 5 Environment Environment Environment Environment This series product should be installed in a cool dry place away from direct sunlight or...

Страница 5: ...mera can resume output normally after you completed the operation Auto Auto Auto Auto exposure exposure exposure exposure The device can automatically set the shutter speed and aperture value according to the video exposure value Negative Negative Negative Negative image image image image This series product can output the negative image The negative image color is contrary to or is compensate for...

Страница 6: ...r the IR camera The IR cut removal is to filter the IR light in the daytime and then auto switch to the general fitter at night This function allows the camera to output the high sensitivity and clear video OSD OSD OSD OSD The camera supports user friendly on screen display menu suitable for various users to select the different functions 1 3 1 3 1 3 1 3 Specifications Specifications Specification...

Страница 7: ...1 60 1 10 000s Image Flip Support Image Freezing Support External Control RS232 9600bps compatible with SONY VISCA protocol Focus Auto manual one time auto focus Focus speed 3 5s from Near to the Far Lens Initialization Built in Exposure Compensation Support Gain Setup Support Aperture Control Support auto manual aperture control Focus Control Support auto manual focus control OSD Support on scree...

Страница 8: ...ramework Framework Framework 2 1 2 1 2 1 2 1 Dimension Dimension Dimension Dimension You can refer to the following three figures for dimension information See Figure 2 1 and Figure 2 2 The unit is mm Figure 2 1 Figure 2 2 ...

Страница 9: ...fer to the following sheet for detailed information Port Function Note Zoom Zoom out Decrease the zoom value Zoom in Increase the zoom value 30 pin port Debug port It is the debug port You can connect to the debug board during the production debug process Zoom in Zoom out 9 pin Control port 30 pin debug port Communication COM 通信串口 Pin 1 Pin 9 ...

Страница 10: ...lashing Note Note Note Note You can connect the debug board to the 30 pin debug port to debug Please note the debug board is not our default accessory You can contact your local retailer to get the board Please refer to the following sheet for 9 pin user connection pin information No Pin Name Note 1 GND 2 VD_LOCK Reserved development port 3 GND_DAC Video GND end 4 VIDEO_OUT Video output end 5 GND ...

Страница 11: ...CAM_WB Auto 8x 01 04 35 00 FF Normal Auto Indoor 8x 01 04 35 01 FF Indoor mode Outdoor 8x 01 04 35 02 FF Outdoor mode One Push WB 8x 01 04 35 03 FF One Push WB mode ATW 8x 01 04 35 04 FF Auto Tracing White Balance Manual 8x 01 04 35 05 FF Manual Control mode One Push Trigger 8x 01 04 10 05 FF One Push WB Trigger CAM_RGain Reset 8x 01 04 03 00 FF Manual Control of R Gain Up 8x 01 04 04 02 FF Down 8...

Страница 12: ...irect 8x 01 04 4D 00 00 0p 0q FF pq Bright Position CAM_ExpComp On 8x 01 04 3E 02 FF Exposure Compensation ON OFF Off 8x 01 04 3E 03 FF Reset 8x 01 04 0E 00 FF Exposure Compensation Amount Setting Up 8x 01 04 0E 02 FF Down 8x 01 04 0E 03 FF Direct 8x 01 04 4E 00 00 0p 0q FF pq ExpComp Position CAM_Backlight On 8x 01 04 33 02 FF Back Light Compensation ON OFF Off 8x 01 04 33 03 FF CAM_Aperture Rese...

Страница 13: ...e reference reference reference only only only only Slight Slight Slight Slight difference difference difference difference may may may may be be be be found found found found in in in in the the the the user user user user interface interface interface interface All All All All the the the the designs designs designs designs and and and and software software software software here here here here ...

Страница 14: ...Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP pe...

Отзывы: