background image

5

5200199 Rev. F

One-Point Ionizer with S Power Supply

5.   If no spark occurs and no arcing is heard, the trouble is in the power supply.  If a spark 

does occur the fault is in one or more of the ionizers.

To find the faulty Ionizer or Ionizers:

1.  Turn OFF current to power supply.
2.   Insert the high voltage cable from one of the ionizers into the exposed hole of one of 

the plastic receptacles and screw knurled plug FINGER TIGHT ONLY.

3.  Turn on the current to the power supply.
4.   Check the ionizer with the Simco-Ion voltage detector.  If it does not light, this is the 

faulty ionizer.  If it does light, add the other ionizers to the power supply until the 

voltage detector fails to light.  The faulty ionizer should be replaced.

5. WARRANTY

This product has been carefully tested at the factory and is warranted to be free from 

any defects in materials or workmanship.  Simco-Ion will, under this warranty, repair 

or replace any equipment that proves, upon our examination, to have become defective 

within one year from the date of purchase.
The equipment being returned under warranty should be shipped by the purchaser to 

Simco-Ion, 2257 North Penn Road, Hatfield PA 19440, transportation prepaid and insured 

for its replacement cost.  Prior to returning any goods for any reason, contact Simco-Ion 

Customer Service at (215) 822-6401 for a Return Authorization Number.  This number 

must accompany all returned items.
This warranty does not apply when the equipment has been tampered with, misused, 

improperly installed, altered, has received damage through abuse, carelessness, accident, 

connected to improper line voltage, or has been serviced anyone other than an authorized 

factory representative.
The warranty does not apply when Simco-Ion parts and equipment have been energized 

by other than the appropriate Simco-Ion electrostatic charging generator or generator, or 

when a Simco-Ion electrostatic charging generator or generator has been used to energize 

other than Simco-Ion parts and equipment.  Simco-Ion makes no warranty, expressed or 

implied, nor accepts any obligation, liabilities, or responsibility in connection with the use 

of this product other than the repair or replacement of parts stated herein.

Содержание Simco ION

Страница 1: ...One Point Ionizer with S Power Supply 5200199 Rev F INSTALLATION AND OPERATING INSTRUCTIONS One Point Ionizer with S Power Supply ...

Страница 2: ...er Supply TABLE OF CONTENTS 1 SAFETY WARNINGS 1 2 INSTALLATION 2 One point Ionizer Location 2 Installation 2 Mounting the Power Supply 3 Cable Supports 3 Grounding 3 Checking for Proper Operation 4 3 MAINTENANCE 4 4 TROUBLESHOOTING 4 5 WARRANTY 5 ...

Страница 3: ...t must be correctly installed and maintained Adhere to the following cautions for safe installation and operation 1 Read the complete Operation Manual before operating Failure to follow instructions may result in damage to the ionizer and or personal injury 2 Disconnect line voltage to power supply before connecting high voltage cable 3 A factory qualified service technician must perform component...

Страница 4: ...ischarged The casing of the one point ionizer should not be less than 3 8 nor more than 3 from the material to be discharged For best operation keep between and 1 The material should not contact the ionizer Installation Mount each ionizer to the machine by means of the mounting clamp provided Wrap the 7 16 clamp around the ionizer and bolt clamp directly to a grounded machine frame or to the perfo...

Страница 5: ... it should be encased in protective plastic tubing available from Simco Ion To install the cable supports press the split bushing out of the metal support and apply the bushing to the cable at the desired location Mount the support then press the bushing with cable back into the support Be sure that a cable support is located to remove all strain and motion from the cable where it enters a static ...

Страница 6: ... their sharpness and decrease efficiency One easy way to remove built up deposits is to occasionally press a soft pencil eraser down over each point in turn and twist slightly Including the one point ionizers in the regular procedure of cleaning the machine will pay dividends in service and excellence of performance 4 TROUBLESHOOTING If equipment fails to function properly check connections to be ...

Страница 7: ...ne year from the date of purchase The equipment being returned under warranty should be shipped by the purchaser to Simco Ion 2257 North Penn Road Hatfield PA 19440 transportation prepaid and insured for its replacement cost Prior to returning any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items ...

Страница 8: ...Point Ionizer with S Power Supply 5200199 Rev F Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2015 Simco Ion Printed in the U S A ...

Отзывы:

Похожие инструкции для Simco ION