10. Faults
Warning:
- Disconnect the power supply before carrying out work on the unit.
- Electrical installation must only be carried out by a skilled electrical engineer.
Table 2, Faults
Problem Cause
Solution
Poor or no suction from
Clean
ION
Filter bag completely filled
Empty filter bag and clean, or
replace filter
Motor operating in wrong
direction
Change direction of motor
rotation
See Section 6.4
Blockage in cleaning system Remove blockage
Clean
ION
does not work
No mains voltage to
Clean
ION
Restore mains voltage
Motor operating on 2 phases Restore voltage of third phase
Overload due to blockage,
thermal overload protection
switched on
Remove blockage and reset
thermal overload protection
See Section 7.3
Defective motor
Have Clean
ION
repaired
Ionisation equipment does
not work or works poorly,
cleans poorly
Ionisation equipment
defective,
cleans poorly
Clean or repair ionisation
equipment (see ionisation
equipment manual)
Power unit is defective
Replace transformer in
switchbox
Thermal overload protection
switched on
See problem
" Clean
ION
does not work"
above
11. Temporary placement out of operation/overhaul/repair
Warning:
- Disconnect the power supply before carrying out work on the unit.
- Repairs must only be carried out by a skilled electrical engineer.
If the Clean
ION
is temporarily not being used:
- Switch off the Clean
ION
and disconnect the mains voltage,
- remove the cover and take out and empty the filter bag (see Section 9),
- clean the entire dust collector,
- replace the filter bag and the cover, and
- store the Clean
ION
in a dry, dust-free location with a maximum ambient temperature of 40º.
- Also see the pump manual.