IQ Power BPS
5201249 Rev. D
Calibration
NOTE
– Calibration should be performed when the system is first installed
and may be performed after the static bar has been cleaned and the system
verified as operating correctly.
If the system is new, perform an initial calibration. The initial calibration sets the
relative nominal ion output for the system. Calibration should only be performed on
IQ Power systems that are new or just cleaned and known to be in proper working
order.
During calibration the target to be neutralized (web, film, etc.) may remain in place,
but MUST NOT BE MOVING. If the web is moving past the static bar (e.g. the
machine is in operation) the calibration will be faulty.
The system should be “on” and in the operating mode (not in start-up, self-test
or power supply number display modes). Press the face label on the power supply
firmly on the word “CALIBRATE”. This will initiate the calibration sequence and
set the relative nominal ion output for the system.
During calibration the system output will be cycled and the three mode lights will
illuminate. At the completion of calibration the speed and distance lights will
flicker. The indicated ion output will be high. The calibration sequence takes
approximately five seconds.
The calibration data is stored in non-volatile memory in the BPS power supply and
used on subsequent power ups.