11
5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
WARNING –
For personal protection, and to ensure proper function, the
GRAY* and BLUE wires must both be connected to ground.
AVERTISSEMENT –
Pour votre sécurité, et pour assurer un bon
fonctionement, les cables GRIS* et BLEU doivent tous deux être connectés
à la terre.
* The GRAY wire may appear GREEN or GREEN/YELLOW on some models.
Le GRIS du cable peut apparaître VERT ou VERT/JAUNE sur certains
modèles.
Figure 8: IQ Easy Static Bar Connector Pin-Out
The pin-out connections are:
1 (brown) +24V
2 (white) COMM A
3 (blue) ground
4 (black) COMM B / internal fault output (Standalone mode only)
5 (gray / green / green-yellow) ground
Set Up
A variety of information can be checked, and operating parameters set, for the IQ
Easy Static Neutralizing Bar through the IQ Power Control Station via the static bar
page / tab. Tap on the device icon for the static bar to access these pages.
To edit or select an operating parameter, tap on the pencil icon to the right of the
parameter description.
Device Name
: A user editable name to identify the specific static bar (14 character).
Bar Type
: A fixed description for the device type (Speed static bar, Hybrid static
bar, etc.)
Bar HV
: Turns the bar HV power supply on/off. Turning the bar HV power off
places the bar in standby, the green indicator on end of bar will begin to flash.