6. TROUBLESHOOTING
• If the Static Bar Checker fails to glow at any of the points, either the cable or the
power supply is defective. To identify the fault, perform the following steps:
a. Turn off power to the Power Supply.
b. Disconnect all static control equipment from the Power Supply.
c. Connect one end of an insulated test wire to the power supply’s ground stud.
d. Energize the power supply. Slowly insert the free end of the test wire into one of
the high voltage receptacles. As the insulated wire approaches the contact within
the terminal, a spark should occur and arcing should be heard. If a spark occurs and
arcing is heard, then the high voltage cable is the cause of the fault. Otherwise, the
power supply is the cause. If either is faulty, contact Simco-Ion Customer Service or
your local Simco-Ion Representative.