Recommended air filtration for the air
heater is 50 micron and must be free of
oil. Additional filtration may be required
depending on applicator used. (Refer to
Applicator manual for required filtration.)
N O T E
N O T E
N O T E
N O T E
N O T E
>
DO NOT
DO NOT
DO NOT
DO NOT
DO NOT operate air heater without a
minimum of 1 SCFM of air flow through
the unit.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
INST
INST
INST
INST
INSTALLA
ALLA
ALLA
ALLA
ALLATION OPTIONS
TION OPTIONS
TION OPTIONS
TION OPTIONS
TION OPTIONS
(See Figure 1)
(See Figure 1)
(See Figure 1)
(See Figure 1)
(See Figure 1)
Heater Pressure Switch Interlock Options for
Activation:
1. Pilot from one of the following items which
corresponds and signals air is flowing:
a. Volume booster - requires a minimum of 1
psig.
b. PLC pneumatic output - requires a minimum
of 1 psig.
c. Air regulator - requires a minimum of 1 psig.
>
Never activate heater without air flow.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
2. Directly from a remote electrical control (such
as a turbine speed control or PLC). This contact
must correspond and signal that air is flowing
through the heater.
This electrical circuit must be connected using a
minimum 1 amp dry contact relay (such as PLC
contact). This can be completed by the following:
1. Remove the present wire from TB8-1.
2. Using a wire nut, connect the wire removed in
step 1 to a longer wire and route to one side of the
remote contact.
3. Run a wire from the other side of the remote
contact back to TB8-1.
4. Add pressure switch changes, A1.
When the remote contact is closed, the air heater
will turn on.