Aerostat PC Heater 5100625-M Rev 9
15
4.5 Ion Output Check
To test the unit for ion output, the use of a charged plate monitor is
recommended. Discharge times can be measured and checked
against the Discharge Specification values in Section 5. If a charged
plate monitor is not available, but a static meter such as a Simco-
Ion handheld electrostatic field meter is available, ion output may be
checked with the following procedure. Take a piece of plastic and
rub it with cloth until a static charge can be read with the static
meter. Turn on the Aerostat PC. Hold the plastic one foot away from
the ionized air outlet for five seconds. Remove the plastic from the
ionized air stream and measure the static charge. The plastic
should be neutralized.
Do not insert objects through the unit's intake or outlet grilles
while in operation. Damage to the ionizer and/or personal
injury may result.
Do not try to verify operation of the unit by drawing a spark
from an ion emitter point. The design of the balancing circuit
makes the "spark test" inconclusive. Sustained grounding of
the ion emitters may damage the balancing circuit.
N'insérez pas d'objets dans l'unité de grilles d'entrée ou de
sortie en cours de fonctionnement. Dommage pour l'ioniseur
et/ou peut entraîner des blessures graves.
Ne pas essayer de vérifier le fonctionnement de l'unité en
dessinant une étincelle provenant d'un émetteur d'ions point.
La conception du circuit équilibrage rend le "contrôle
d'allumage" non concluantes. Mise à la terre soutenue des
émetteurs d'ions peut endommager le circuit l'équilibrage.
Содержание 4003367
Страница 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Air Blower Aerostat PC with Heater User s Manual ...
Страница 6: ...Aerostat PC Heater 5100625 M Rev 9 1 1 Description 1 1 Aerostat PC Ionizing Air Blower ...
Страница 9: ...Aerostat PC Heater 5100625 M Rev 9 4 2 Installation 2 1 Unpacking 2 2 Location 2 3 Electrical ...
Страница 13: ...Aerostat PC Heater 5100625 M Rev 9 8 3 Operation 3 1 Controls Indicators ...
Страница 23: ...Aerostat PC Heater 5100625 M Rev 9 18 5 Specifications 5 1 Specifications 5 2 Parts Accessories ...