Operation Manual – ITW GSE 4400 Tier 4
changed. Press the up or down arrow buttons to change the selection. Press the center
●
button to
record the new value. Press the LEFT arrow button to exit the submenu and return to the submenu list.
16) Modbus Slave Address
If the unit will be part of an RS-485 Modbus RTU BMS/RMS monitoring system, it must be assigned a
Modbus Slave Address. This sub-menu allows the user to enter the slave address.
Go into the Setup Menu and then scroll up or down to the Modbus Slave Address submenu. Press the
center
●
button to enter the submenu, and then press the
●
button again to allow the value to be
changed. Press the up or down arrow buttons to change the selection. Press the center
●
button to
record the new value. Press the LEFT arrow button to exit the submenu and return to the submenu list.
17) LED Brightness
The unit status LED’s have three brightness levels. The default is set to medium.
Go into the Setup Menu and then scroll up or down to the LED Brightness submenu. Press the center
●
button to enter the submenu, and then press the
●
button again to allow the value to be changed. Press
the up or down arrow buttons to change the selection. Press the center
●
button to record the new
value. Press the LEFT arrow button to exit the submenu and return to the submenu list.
18) Unit of Measure
This submenu is used to set the unit of measurements to Metric or Imperial.
Go into the Setup Menu and then scroll up or down to the Unit of Measure submenu. Press the center
●
button to enter the submenu, and then press the
●
button again to allow the value to be changed. Press
the up or down arrow buttons to change the selection. Press the center
●
button to record the new
value. Press the LEFT arrow button to exit the submenu and return to the submenu list.
19) 28V Voltage
This Setup submenu allows the 28 volt output to be adjusted between 19.0 VDC and 33.0 VDC using
the UP and DOWN navigation buttons. (Please note that the acceptable voltage range for all
commercial DC powered aircraft is 26V to 29V.
Enter the Setup Menu and then scroll up or down to the ARU Voltage submenu. Press the center
●
button to enter the submenu, and then press the
●
button again to allow the value to be changed. Press
the up or down arrow buttons to change the selection. Press the center
●
button to record the new
value. Press the LEFT arrow button to exit the submenu and return to the submenu list.
20) 28V Compensation
DC voltage drops quickly as the current increases over a given length of cable. This Setup submenu
allows the 28 volt output to be automatically adjusted as the load increases. The allowed setting is
between 0.0 and 3.0 VDC at the rated continuous load of the unit. Note that the maximum output
voltage of the unit is 33 VDC.
Enter the Setup Menu and then scroll up or down to the 28V Compensation submenu. Press the center
●
button to enter the submenu, and then press the
●
button again to allow the value to be changed.
Press the up or down arrow buttons to change the selection. Press the center
●
button to record the
new value. Press the LEFT arrow button to exit the submenu and return to the submenu list.
21) Current Limit Step Size
If too much current is supplied to an aircraft engine, it is possible for the engine to shear the propeller
shaft. The Current Limit should be set to the maximum current the aircraft to be powered can take (per
the aircraft manufacturers recommendations). The Current Limit is set using the UP and Down arrows
on the Operators Panel. This submenu is used to set the step size the current limit is changed by every
time the UP or Down button is pressed. The current limit settings are from 300 amps to 2000 amps in
steps of 50/100/200/300 amps. This menu selects the size of the steps that the operator uses to adjust
the current limit before turning on the 28 VDC to the aircraft.
OM2247 Rev B
Page 48 of 125
Содержание 4400 Tier 4
Страница 27: ...Operation Manual ITW GSE 4400 Tier 4 OM2247 Rev B Page 26 of 125 ...
Страница 42: ...Operation Manual ITW GSE 4400 Tier 4 OM2247 Rev B Page 41 of 125 ...
Страница 44: ...Operation Manual ITW GSE 4400 Tier 4 OM2247 Rev B Page 43 of 125 ...
Страница 52: ...Operation Manual ITW GSE 4400 Tier 4 c Black Box OM2247 Rev B Page 51 of 125 ...
Страница 56: ...Operation Manual ITW GSE 4400 Tier 4 OM2247 Rev B Page 55 of 125 ...
Страница 106: ...Operation Manual ITW GSE 4400 Tier 4 This page is intentionally left blank OM2247 Rev B Page 105 of 125 ...
Страница 112: ...Operation Manual ITW GSE 4400 Tier 4 A 6 Additional menu items for ARU OM2247 Rev B Page 111 of 125 ...
Страница 123: ...OM2247 Rev B Page 122 of 125 ...
Страница 124: ...OM2247 Rev B Page 123 of 125 ...
Страница 125: ...OM2247 Rev B Page 124 of 125 ...
Страница 126: ...OM2247 Rev B Page 125 of 125 ...