14
Integrated Technical Vision
http://www.itvsystems.com.ua
Outputs’ use and operation modes
All outputs of the panel can be programmed at will one of the use variants: lock,
bell, alarm or programmed output. Moreover every output is set an operational
mode: start-stop (an output is activated whilst the proper command is present, for
example, during the time of control panel Alarm mode), impulse (an output is
activated for the programmed time), trigger (at first event an output is activated, at
the next event it is switched off), and continuous.
Access Denial
Access may be denied to cardholder for the following reasons:
-
Panel was not downloaded (reader's LED does not light or blink)
-
ID was not enrolled in panel (on ID passing panel switches reader's red
LED and buzzer for 1 second)
-
ID expired (on ID passing panel switches reader's red LED and buzzer for
1 second)
-
Access is not allowed according to the schedule (on ID passing panel
switches reader's red LED and buzzer for 1 second)
-
Antipassback violation (on ID passing panel switches reader's red LED
and buzzer for 1 second)
-
Lost or Blocked ID passed (on ID passing panel switches reader's red LED
and buzzer for 1 second)
-
Access point is in alarm mode (reader's red LED lights constantly)
-
Access point is in blocked mode (reader's red LED lights constantly)
Alarm Mode
In alarm mode reader's red LED lights constantly.
Access point goes into alarm mode for following reasons:
-
In case of door ajar
-
Panel box tampering (both Access points)
-
Attempt of access with lost ID
-
If door is opened too long (door time expired)
-
In case of attempt of code matching (if switched on during programming).
In alarm mode the panel activates outputs assigned for BELL and ALARM.
Alarm output is deactivated when panel switches into the mode different from
alarm mode and BELL output is deactivated after programmed time.
If access point is in alarm mode to pass through this point is prohibited. RTE
button unlocks the door.
To switch alarm mode off, pass card with "Alarm OFF" sign or with command
from computer.
Free Pass mode
Sometimes the conditions arise when door should be opened for free pass for
everyone, in case of fire, earthquake or other disaster, for instance. For this
case panel has free pass mode.
Control Panel Operation
Содержание NDC-F18
Страница 1: ...NDC F18 Access Control Panel Installation Manual NDC F18 A C C C E S S C O N T R O L P A N E L ...
Страница 2: ...2 Integrated Technical Vision http www itvsystems com ua ...
Страница 4: ...4 Integrated Technical Vision http www itvsystems com ua ...
Страница 23: ...http www itvsystems com ua Integrated Technical Vision Ltd 23 ...