- Door is opened too long (door time expired)
- Attempt of code matching (if the function is switched on during programming).
Alarm output is activated, but the mode does not switch on in case of panel box
tampering attempt.
You can disable control panel switching into Alarm mode in case of "Door opened
too long" event, the inhibition is set for each access point separately.
In alarm mode panel activates outputs assigned for BELL and ALARM. Alarm output
is deactivated when panel switches into the mode different to alarm mode and
BELL output is deactivated after the programmed time.
If access point is in the alarm mode, passing through this point is prohibited. RTE
button unlocks the door.
Pass the ID with “Alarm OFF” sign to switch alarm mode off or do it with command
from computer.
Free Pass Mode
Sometimes the situations arise when a door should be open for free pass to
everyone, e.g. in case of fire, earth quake or any other disaster. In such cases
the panel switches to the Free Pass mode.
In this mode reader LED blinks green and yellow alternately.
Access point switches into the Free Pass mode with the operator command or if
the input, programmed as “Free Pass” is broken.
Access point is in Free Pass Mode until this input is shorted or the operator
cancels the mode.
While Access point is in Free Pass mode locking device is locked and the panel
does not respond to IDs' passing, PIN entry or RTE button pressing.
The control panel allows you assigning of Blocking function to an input for one
access point A, B or two access points together (A + B).
Blocked Mode
The Blocked Mode is designated for situations when access to the premises
should be prohibited to everyone, in case of security alarm for instance. When
Access point is in the Blocked mode access is granted only to cardholders of
IDs with “Security Service” sign. Door cannot be unlocked with RTE button.
Reader LED blinks red and yellow alternately during Blocked mode time.
Access point switches into the Blocked mode with operator command or when
the input, programmed as “Blocking” is broken. Access point remains in the
blocked mode until this input is shorted or the operator cancels the mode.
The control panel allows you assigning of Blocking function to an input for one
access point A, B or two access points together (A + B).
Control Panel Operation
Содержание NDC-B052
Страница 1: ...NDC B052 Access Control Panel Installation Manual NDC B052 A C C E S S C O N T R O L P A N E L ...
Страница 2: ...2 Integrated Technical Vision Ltd http www itvsystems com ua ...
Страница 4: ...4 Integrated Technical Vision Ltd http www itvsystems com ua ...
Страница 6: ...6 Integrated Technical Vision Ltd http www itvsystems com ua ...
Страница 23: ...http www itvsystems com ua Integrated Technical Vision Ltd 23 ...