REMOTE MR 400 INSTALLATION

 

 
STEP 5: ONLY FOR GREATER DISTANCES THAN 5 METERS BETWEEN UNITS 

 

If the distance between the remote condenser and the split is greater than 5 meters, it 
is necessary to add some refrigerant. Add 40 grams per extra meter, up to 15 meters 
maximum. 
  

STEP 6: START UP 

 

Now the split unit can be turn on to try it, and modified the control parameters if need 
it (electronic board).  Instruccions in the user manual. 

 

 
 
NOTE: It is better to use the ambient probe from the split unit to obtain the temperature of 
the air getting inside the remote condenser (in the air intake of the condenser). To do so, 
enlarge the probe cable and put the probe in the condenser. 
 

Содержание MR 400

Страница 1: ...es not need communication with the split unit To connect remove the rear cover using a Torx screwdriver The electrical cable must go through the hole next to the piping hole Use a 3x1 5 mm2 electrical cable Terminal connector to supply electrical power to the remote condenser located behind the metallic cover Level the unit correctly Locate the remote condenser unit under a shadow We advise to pla...

Страница 2: ...denser always install the unit with the air direction out to the ambient when installed in a wall to avoid condensed air returning to the condenser If more than one unit is going to be installed please located them to avoid the condensed air going from one unit to the other ...

Страница 3: ...wed to let the water drain directly Level the unit correctly Always check the ice exit to allow the ice cubes fall free In case of stacking two units please follow the stacking manual STEP 2 REFRIGERATION CONNECTION BETWEEN BOTH UNITS REMOTE CONDENSER Remove the rear cover if need it REMOTE CONDENSER PIPING CONNECTION Gas pipe up inlet 1 2 Liquid pipe down outlet 3 8 The remote condenser is sent f...

Страница 4: ... oil staying at the condenser Do not install the remote condenser lower than 3 meters from the split unit If the remote condenser higher or equal to the split unit a siphon must be installed in the gas line one every 4 vertical meters and one every 8 horizontal meters SPLIT UNIT It is connected by a gas tap 3 8 and a liquid gas tap using the nut that comes with the tap STEP 3 INSTALLATION LEAKING ...

Страница 5: ... extra meter up to 15 meters maximum STEP 6 START UP Now the split unit can be turn on to try it and modified the control parameters if need it electronic board Instruccions in the user manual NOTE It is better to use the ambient probe from the split unit to obtain the temperature of the air getting inside the remote condenser in the air intake of the condenser To do so enlarge the probe cable and...

Отзывы: