ICE QUEEN
TECHNICAL SERVICE MANUAL
16
IQ 135 S60
5
0
1
0
3
6
9
Ice discharge slot
Water trough overflow
Height increases by 80 mm
when feet are fitted
Rating Plate
Serial number
Cooling water drain (water-cooled models)
Electrical connection
Water inlet
Ice bin drain
MODEL
ICE BIN
STORAGE
CAPACITY
(KG)
COOLING
WATER
CONSUMPTION
(L/Hour)
WATER
CONSUMPTION
(L/Hour)
NET
WEIGHT
(KG)
DIMENSIONS
(CRATED)
X*Y*Z
GROSS
WEIGH
T
(KG)
VOLUME
(M
3
)
IQ 135 A
60
5.5
70
615x650x1465
85
0.58
IQ 135 W
60
40
5.5
68
615x650x1465
83
0.58
MODEL
REFRIGERANT
CHARGE
(gr)
HIGH PRESURE
LOW
PRESURE
AVERAGE
TOTAL
AMPS
(2)
(A)
FUSE
RATING
(A)
COMPRESSO
R POWER
(1)
(W)
TOTAL
POWER
(2)
(W)
MINIMUM
MAXIMUM
Kg/cm
2
Psi
Kg/cm
2
Psi
Kg/cm
2
Psi
IQ 135 A
500
16
228
17
242
2.5
35
4.2
16
360
650
IQ 135 W
360
16
228
17
242
2.5
35
4.2
16
360
650
(1) Data obtained at room temperature 20°C, water introduced at 15°C; water quality = 500ppm
(2) Maximum consumption obtained at room temperature = 43°C, according to UNE climate classification, Class T
(TROPICALISED).
NOTE: Expansion controlled by capillary.
Содержание GIQ 1100
Страница 6: ...ICE QUEEN TECHNICAL SERVICE MANUAL 6 1 4 Wiring diagrams ...
Страница 7: ...ICE QUEEN TECHNICAL SERVICE MANUAL 7 ...
Страница 8: ...ICE QUEEN TECHNICAL SERVICE MANUAL 8 ...
Страница 9: ...ICE QUEEN TECHNICAL SERVICE MANUAL 9 ...
Страница 10: ...ICE QUEEN TECHNICAL SERVICE MANUAL 10 ...
Страница 11: ...ICE QUEEN TECHNICAL SERVICE MANUAL 11 ...
Страница 12: ...ICE QUEEN TECHNICAL SERVICE MANUAL 12 ...