3.4.- ELECTRICAL CONNECTION
IT IS MANDATORY TO GROUND THE EQUIPMENT
To avoid possible discharges on individuals or damages to the equipment, the machine should be grounded pursuant local
and/or national regulations as the case may be.
THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE OF DAMAGES ARISING DUE TO THE LACK OF THE GROUND
INSTALLATION
At the back of the machine there is a junction box for electrical service conexion.
The machine should be places in such a way as to allow a minimum space between the back and the wall to allow an easy access and
without risks to the junction box.
It is advisable to install a power switch and the appropriate electrical safety devices in accordance with local, state and/or national
regulations in each case.
Voltage and tension are indicated in the nameplate. Variation on voltage above the 10% stated on the nameplate could result
on damages or prevent the machine start-up.
ATTENTION: The appliance requires an independent power supply of proper capacity. See the nameplate for electrical
specifications. Failure to use an independent power supply of proper capacity can result in a tripped breaker, blown fuse,
damage to existing wiring, or component failure. This could lead to heat generation or fire.
3.5.- INSTALLATION THE EQUIPMENT ABOVE TANKS/BINS
The modular ice makers (IMH) must be installed on tanks or bins, following the instructions contained in this manual.
The strength and stability of the container-machine/s assembly must be verified, as well as the fixing of the elements.
The drain must be lower than the drainage area of the tank/bin and the hose must always be in a descending position, NEVER rising,
(Figure IV).
IT IS IMPORTANT THAT THE WATER PIPE DOES NOT PASS BY OR GO NEAR HEAT SPOTS AS THIS WILL AFFECT ICE
PRODUCTION