Figure 4: Direct connect alignment
The faces and outside diameters of the coupling halves must be square and concentric with the bores.
Good alignment is achieved when the dial indicator readings, for both parallel and angular misalignment,
are 003in. (.076mm) Total Indicated Reading (T.I.R.) or less when the pump and driver are at operating
temperature (Final Alignment). Fig. 2 provides a picture of what to look for.
Setup
1.
Mount two dial indicators on one of the coupling halves (X) so that hey contact the other coupling
half (Y), see Fig. 3.
5.1 Installation Instructions-Vertical Pumps
16
Model VJC Installation, Operation, and Maintenance Manual