Operating Instruction Jumper Cable Rev. -
Page
17
of
27
GENERAL DATA OF ECCE (PLUG) & ECCV (CONNECTOR)
Description
Value
Applied standard
IEC 62196-2
Charging mode
Mode 2 & 3B (IEC 61851)
Max. operating temperature
+50 °C
Min. operating temperature
-30 °C
Max. operating voltage
240 V-AC (Single phase)
480 V-AC (Three phase)
Rated current
20 A, 32 A, 63A
Max. application height above sea level
2000 m
Degree of protection
IP44
Item
Designation
Item
Designation
1
L1 (Line 1)
8
Connection Cable
2
PP/CS/CC (Proximity)
9
N (Neutral)
3
CP (Control Pilot)
10
CP (Control Pilot)
4
N (Neutral)
11
PP/CS/CC (Proximity)
5
L2 (Line 2) for 3Phase only
12
L1 (Line 1)
6, 14
PE
13
L3 (Line 3) for 3Phase only
7
L3 (Line 3) for 3Phase only
15
L2 (Line 2) for 3Phase only
Table 9: Contact arrangement for ECCE & ECCV Jumper Cable
1
2
3
4
6
7
5
8
10
9
11 12
14
15
13
Figure 9: Connector Overview, left side: ECCE (Plug); right side: ECCV (Connector)
Table 8: Specifications for ECCE & ECCV Jumper Cable
EXPORT CODE C
COMMERCIAL. RESTRICTED TO EMBARGOED COUNTRIES AND DENIED PARTIES.
PRINTED COPIES ARE NOT MAINTAINED TO LATEST REVISION.