Drill
•
Feeler gauges
•
Hex wrenches
•
Induction heater
•
Lifting sling
•
Micrometers (inside and outside)
•
Open end wrenches
•
Press
•
Soft face hammer
•
Spanner wrench
•
Spanning type puller
•
Tap
•
Torque wrench with sockets
•
Lifting eyebolt (dependent on pump / motor size)
6.4.3 Prepare for disassembly
1.
Close the isolation valves on the suction and discharge sides of the pump.
2.
Drain the liquid from the piping; flush the pump if necessary.
3.
Disconnect all auxiliary piping, tubing, and equipment that will interfere with the removal of the head
and the rotor.
4.
Remove the oil drain plugs (408A) from the bottom of the bearing housings (134, 134A) and drain
the oil.
Dispose of the oil in accordance with applicable regulations.
234B
501B
234A
235B
408A
408A
233
232
Figure 38: Coupling guard disassembly
5.
Remove the oiler bottle (251) and store it in a safe place.
6.
Remove the coupling guard (501B).
Refer to Remove the coupling guard in the Commissioning, Startup, Operation, and Shutdown
chapter.