Table 2: Temperature class definitions
Code Maximum permissible
pumpage temperature in °C | °F
Minimum permissible pumpage temperature in °C | °F
T1
450 | 842
372 | 700
T2
300 | 572
277 | 530
T3
200 | 392
177 | 350
T4
135 | 275
113 | 235
T5
100 | 212
Option not available
T6
85 | 185
Option not available
The code classification marked on the equipment must be in accordance with the specified area where
the equipment will be installed. If it is not, do not operate the equipment and contact your ITT Goulds
Pumps sales representative before proceeding.
The CE and the Ex designate the ATEX compliance. The code below reads as follows:
II = Group 2
2 = Category 2
G/D = Gas and Dust present
T4 = Temperature class, can be T1 to T6 (see Table)
The code classification marked on the equipment must be in accordance with the specified area where
the equipment will be installed. If it is not, do not operate the equipment and contact your ITT Goulds
Pumps sales representative before proceeding.
5 ATEX Considerations and Intended Use
10
HSU Installation, Operation and Maintenance Instructions