CANNON STANDARD
page 13 of 20
ASSEMBLY AND WIRING INSTRUCTION
CA-BAYONET IP69K
Circular Connector with Protection Class IP69K
CAS25092E
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU/FA
AKU/FA
G5820W
JPE 18.12.2018
ITT Cannon GmbH, D-71384 Weinstadt
5.3 Removal of Contacts
1. All accessories are removed in reversed direction as described in the assembly instruction.
2. Use the correct removal tool as described on 3.4.
3. Place tool from the mating side parallel to their axis over the socket or pin contact. Apply smooth and
continuous pressure toward the rear end of the connector to push contact out of the insulator. The
operation is terminated as soon as the shoulder of the tool butts against the front of the insulator.
4. Pull tool carefully out of the connector.
Extraction Tools.
5.4 Assembly Instruction for the Universal Endbell
1
Make sure, that the sealing ring is mounted and greased.
2
Move the coupling nut on the barrel.
Mount the O-ring on the barrel.
Pay attention that the O-ring is not twisted (water
tightness!).
3
Move the shielding ring to the barrel, pay attention to the
tooth pitch.
Remove the tape
Disentangle the shielding braid and arrange it evenly round
over the shielding ring.