SHUTDOWN
1.
Slowly close discharge valve.
2.
Shut down and lock driver to prevent accidental
rotation.
s
!
WARNING
When handling hazardous and/or toxic fluids,
proper personal protective equipment should
be worn. If pump is being drained, precautions
must be taken to prevent physical injury.
Pumpage must be handled and disposed of in
conformance with applicable environmental
regulations.
FINAL ALIGNMENT
Alignment procedures must be followed to
prevent unintended contact of rotating
parts. Follow coupling manufacturer's
coupling installation and operation
procedures.
1.
Run the unit under actual operating conditions for
a sufficient length of time to bring the pump and
driver and associated system up to operating
temperature.
2.
Remove coupling guard. Refer to coupling guard
installation and disassembly instructions in
Appendix II
.
3.
Check alignment while unit is still hot per
alignment procedure in the
Installation
Section.
4.
Reinstall coupling guard. Refer to coupling guard
instruction in
Appendix II
.
ANSIFAM IOM - 12/03
43
4
Содержание Goulds Pumps 3196
Страница 1: ...Installation Operation and Maintenance Instructions ANSI FAMILY ...
Страница 4: ...4 ANSIFAM IOM 12 03 ...
Страница 6: ...6 ANSIFAM IOM 12 03 ...
Страница 10: ...10 ANSIFAM IOM 12 03 ...
Страница 12: ...This Page Intentionally Left Blank 12 ANSIFAM IOM 12 03 ...
Страница 28: ...BASEPLATE LEVELING WORKSHEET 28 ANSIFAM IOM 12 03 ...
Страница 44: ...44 ANSIFAM IOM 12 03 ...