background image

DISASSEMBLE

Upper Housing 

1.  Remove switch (9). Disconnect switch wires.

Upper Housing

2.  Loosen but do not remove four pump head screws and

carefully remove upper housing assembly (1)

3.  Inspect check valve (2) for debris
4.  Reassemble new upper housing (1)

Check Valve Assembly

Follow steps 2

3.  Replace check valve (2)
4.  Reassemble upper housing (1)

Lower Housing, Diaphragm, Motor

Follow step 2

3.  Rotate lower housing (4) so mounting notch opening on lower

housing exposes set screw which holds bearing housing to
shaft.

4.  Loosen this set screw by inserting wrench 1/8” Allen wrench

into mounting notch opening. Then, slide lower housing (4) off
motor shaft.

Diaphragm Cont’d 

5. Loosen four cam piston screws with Phillips head screw

driver and pull apart cam from inner pistons. (Pistons should
always be replaced when a new diaphragm is installed.)

Motor Cont’d

5. Replace Motor

REASSEMBLE

Motor

1. Reassemble lower housing assembly (4) to motor. (Follow

steps 4 to 10.)

Diaphragm

2.  Lower housing is assembled with:

•  Flat side of diaphragm and outer pistons facing motor
•  Hex stem of inner pistons must be aligned into hex holes in

outer pistons (4).

• Outer pistons must be aligned with alignment slots on cam

assembly making sure screw holes align in cam assembly,
otherwise diaphragm will leak.

3. Tighten cam piston screws partially, center piston in

diaphragm, then tighten screws securely (18 in. lbs. torque)

Lower Housing

4.  Reassemble lower housing assembly (4) to motor.
5. Retighten set screw securely. Set screw head must be

positioned facing motor covering seam (indentation).
(Positioning of this screw is critical to avoid misalignment and
subsequent diaphragm damage.)

Upper Housing, Check Valve

6.  Reassemble upper housing (1) 
7.  Properly seat O-Ring in check valve assembly (2) and check

if ferrules and screen are in place on upper housing (1)

8.  Install check valve (2) into upper housing (1) and push in.
9.  Assemble on to lower housing (4), align 4 screws on to motor

by rotating lower housing (4) if necessary to align feet.

10.  Tighten screws evenly to 30 in. lbs. torque.

Pressure Switch

1.  Place switch against front of pump (9), insert screws and take

care not to cross thread or strip out threads in housing.

2. Reconnect wires.

TROUBLESHOOTING

WARNING: 

BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM!!

Failure to Prime -

Motor operates, but no pump discharge

• Restricted intake or discharge line
• Air leak in intake line
• Debris in pump
• Punctured pump diaphragm (pump leaks)
• Crack in pump housing

Motor falls to turn on

• Loose wiring connection
• Pump circuit has no power
• Blown fuse
• Pressure switch failure
• Defective motor
• Open thermal protector

Pulsating Flow 

• Restricted pump delivery. Check discharge lines, fittings and

valves for clogging or undersizing

Pump Fails to Turn Off After All Fixtures Are Closed

•  Empty water tank
•  Insufficient voltage to pump (low battery)
•  Punctured pump diaphragm (pump leaks)
•  Discharge line leak
•  Defective pressure switch

Low Flow and Pressure

• Air leak at pump intake
• Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm (pump leaks)
• Defective motor

2

1

4

Includes items 1 thru 4

9

6

3

5

Quite often when a pump is worn or defective the one failed component has overburdened others. To avoid frequent aggravating
repairs, Flojet offers service kit assemblies making repairs as quick and easy as possible.

Содержание Flojet 4305-144D

Страница 1: ...turn switch off and see the trouble shooting guide As a circulation pump always run full flow with no restriction Use 3 5 GPM pump for tanks up to 30 gallons and use 5 0 GPM pump for tanks up to 50 gallons Divert excess water but do not restrict flow For portable use we recommend the pump be mounted on a base i e 3 4 x 8 x 10 board or plywood add a length of cable with alligator clips for battery ...

Страница 2: ...then pump head mounts while supporting weight of pump STEP 5 Use 3 4 or 5 8 I D flexible hose preferably braided or reinforced Use hose clamps on the slip on barb hose connectors STEP 6 Install a 40 mesh in line strainer in accessible location between tank and pump inlet INSTALLATION STEP I Use 14 gauge stranded wire to 20 12 gauge to 50 from power source STEP 2 Use a 15 amp rated on off switch on...

Страница 3: ...ritical to avoid misalignment and subsequent diaphragm damage Upper Housing Check Valve 6 Reassemble upper housing 1 7 Properly seat O Ring in check valve assembly 2 and check if ferrules and screen are in place on upper housing 1 8 Install check valve 2 into upper housing 1 and push in 9 Assemble on to lower housing 4 align 4 screws on to motor by rotating lower housing 4 if necessary to align fe...

Страница 4: ...from FLOJET During this one year warranty period FLOJET will at its option at no charge to the customer repair or replace this product if found defective with a new or reconditioned product but not to include costs of removal or installation No product will be accepted for return without a return material authorization num ber All return goods must be shipped with transportation charges prepaid Th...

Отзывы: