Installation and Operation Guide
3-16
Figure
3-21. Call Manipulation Window
The Call Manipulation window includes up to 10 different Cellular numbers
strings with a maximum of 5 digits each. For each entry there is a rule to
make changes in the detected CLI number. When the system detects an
incoming call from the Callback/Call Through database user, the CGW-D calls
back to the number, which is changed according to the rule from the Call
Manipulation window.
Item
Function
Default
Range/
Option
Public Call Through
Allow Public Call
Through
Enables to provide a dial tone to any incoming
cellular caller, which can make calls subject to the
restrictions set in
Prefix Restriction Numbers
window and
Max. Digits to Dial
parameter.
Deselected
Max. Digits to Dial Contains a value that limits the number of digits
that a cellular caller can dial. Active only when
Allow Public Call Through
checkbox is selected.
Inactive
Enable Restriction
Table
Applies the settings defined in the restrictions
table.