Link to the 2.4GZ OpenWay Gas Module

 

LED 
color 

# of 
blinks 

Definition 

Action 

The gas module could not join to 
the range extender. 

 

If the range extender's install 
window has not yet expired, retry 
step 1. 

 

If the install window has expired, 
repeat the procedure 

Link to a 

CENTRON Meter

 on page 8. 

After verifying the signal quality 
on the range extender, 
immediately return to this section 
and repeat step one. 

 

If the gas module still does not 
join the range extender, the range 
extender should be relocated to a 
more suitable location, either 
away from physical barriers and 
obstructions to provide a clearer 
path to the gas module or 
physically closer to the gas 
module. Afterwards, repeat the 
procedure 

Link to a CENTRON 

Meter

 on page 8.  

None 

2.

 

After establishing a connection between the gas module and the range extender, return 
to the range extender and verify the signal quality.   

The status of the connection with the gas module is indicated by the blink pattern of 
the green LED. The green LED repeats its blink pattern every minute for the duration 
of the install window. 

 

LED 
color 

# of 
blinks 

Definition 

Action 

Green 

Poor signal quality. 

Relocate the range extender and repeat 
the install process from the procedure 

Link to a CENTRON Meter

 on page 

8. 

Green 

2-5 

Acceptable signal quality. 

No action is needed. 
If the signal quality is two blinks or 
better, an acceptable radio link has 
been established between the range 
extender at its temporary mounting 
location and both the CENTRON 
meter and the gas module.  

 

DRAFT  OpenWay Installation Guide 

11 

 

Содержание OpenWay OWR-1000-001

Страница 1: ...OpenWay 2 4ZR IPP Range Extender Installation Guide DRAFT OpenWay...

Страница 2: ...erence This device must accept any interference that may cause undesirable operation This device must be permanently mounted such that it retains a distance of 20 centimeters 7 9 inches from all perso...

Страница 3: ...on Flowchart 5 Configure the 2 4ZR IPP Range Extender 6 Reconfigure an Installed 2 4ZR IPP Range Extender 7 Read an Installed 2 4ZR IPP Range Extender 8 Select a Mounting Location 8 Link to a CENTRON...

Страница 4: ...Contents iv DRAFT OpenWay Installation Guide...

Страница 5: ...or laptop computer loaded with Endpoint Link or Endpoint Link Pro software version 5 4 or higher OpenWay Belt Clip Radio AMI 0100 001 2 4GZ OpenWay Gas Module Installation Guide TDC 0816 xxx Equipment...

Страница 6: ...Before You Begin vi DRAFT OpenWay Installation Guide...

Страница 7: ...onents or there may be too great a distance between the meter and the gas module The range extender is strategically placed between the meter and the gas module providing an extension to the gas modul...

Страница 8: ...tional specifications Description Power source Two A cell lithium batteries Tamper detection None FCC compliance Part 15 certified Intrinsic safety UL Class I Division 1 Groups C and D Product identif...

Страница 9: ...e Model OWG 5001 xxx or later with IPP Related Documents 2 4GZ OpenWay Gas Module Installation Guide Direct Mount TDC 0816 xxx Endpoint Link Pro Server Software User s Guide TDC 0737 xxx Endpoint Link...

Страница 10: ...Chapter 1 Introduction 4 DRAFT OpenWay Installation Guide...

Страница 11: ...list in the order listed Installation Checklist Step Procedure 1 Configure the 2 4ZR IPP Range Extender on page 6 2 Select a Mounting Location on page 8 3 Link to a CENTRON Meter on page 8 4 Link to t...

Страница 12: ...ons parameters with a Bluetooth enabled FC200 handheld computer or a laptop computer loaded with Endpoint Link or Endpoint Link Pro software the OpenWay Belt Clip Radio and the same configuration file...

Страница 13: ...d computer running Endpoint Link software 3 Using Endpoint Link verify successful configuration of the range extender Note If the 2 4GZ OpenWay Gas Module is not yet programmed then it should be progr...

Страница 14: ...faces until the final location is verified If the range extender can be mounted within sight of the meter and the gas module the location is probably adequate Select a location for the range extender...

Страница 15: ...e the radio joining process hold the Itron magnet on the side of the range extender over the label for approximately five seconds and then remove the magnet The range extender searches for CENTRON met...

Страница 16: ...procedure in the order listed in the Installation Checklist on page 5 The radio link from the range extender to the CENTRON meter must be established before you establish a link to the gas module You...

Страница 17: ...rds repeat the procedure Link to a CENTRON Meter on page 8 None 0 2 After establishing a connection between the gas module and the range extender return to the range extender and verify the signal qua...

Страница 18: ...tender in the optimum location determined by the procedures Link to a CENTRON Meter on page 8 and Link to the Gas Module on page 10 3 Using two screws mount the device to a stationary object Caution D...

Страница 19: ...he steps in Configure the 2 4ZR IPP Range Extender on page 6 Repeat the steps in Link to a CENTRON Meter on page 8 Important The order in which you perform the magnet swipes when setting up RF paths i...

Страница 20: ...Chapter 3 Troubleshooting 14 DRAFT OpenWay Installation Guide...

Страница 21: ...entification 2 installation 5 installation flowchart 5 installation overview 5 intrinsic safety 2 L location 8 M magnet v materials 2 meter compatibility 2 modulation 2 mounting 12 O operating humidit...

Страница 22: ...Index 16 DRAFT OpenWay Installation Guide...

Отзывы: