Chapter 2  Installing the 60WP Endpoint 
 

26 

Water Solutions 60WP Endpoint Installation Guide 

 

Figure 7: Wrong Position for Spacers - Spacers are not supported! 

 

A Unsupported 

foam 

spacer 

 

4.

 

The installed position of the endpoint should be vertical and upright when the lid is 
replaced on the pit. 

 

IMPORTANT!

 Any endpoint position other than upright may negatively affect radio 

performance and battery life. 

 

 

Содержание 60WP Endpoint

Страница 1: ...Water Solutions 60WP Endpoint Installation Guide Water Solutions...

Страница 2: ...erating transmitters and receivers and cannot be shipped by air All product returns must be shipped by ground transportation Repairs and Modifications WARNING Attempts to repair this device by unautho...

Страница 3: ...on 11 Wall Mount Installation 16 Required Tools and Hardware Wall Mount Installation 16 Installing Using a Wall Mount 16 Through Lid Mounting 18 Pit Lids with Holes 18 Required Tools and Hardware 18 I...

Страница 4: ...Contents iv Water Solutions 60WP Endpoint Installation Guide...

Страница 5: ...antly reduced as the meter is located deeper in the pit box When a point is reached where read reliability is compromised a new installation method must be selected How This Document is Organized This...

Страница 6: ...Overview on page 10 for a diagram of the installation process WARNING This type of note is used to warn of potential physical harm to the user or hardware It is critical that you pay strict attention...

Страница 7: ...riod will be reset Tamper Indicators To minimize the possibility of theft the 60WP Endpoint features cut cable tamper reporting as well as a security seal to indicate physical tampering A cut cable ta...

Страница 8: ...tays in Programming Mode for 15 minutes For the location of the magnet see Activating Programming Mode on page 31 NOTES Hold the magnet in position for three seconds to activate Programming Mode If it...

Страница 9: ...over for inline connector and tamper seal for security ERW 0771 301 Figure 1 OR 60WP endpoint with a 5 foot cable ERW 0771 311 Figure 2 NOTE The 6 inch cable variant is only available to meter manufac...

Страница 10: ...r pit box environment Use Panduit PLT4H 76 or equivalent cable ties for outdoor and pit box applications Through Lid Mounting kit Itron part number CFG 0771 010 Minimum order 36 Shelf Mount Adaptor It...

Страница 11: ...od material see information under Compatibility Chart at the following Itron website address www itron com pages products_detail asp ID itr_000428 xml pgtype subID ar WARNING You must ensure that the...

Страница 12: ...Guide The following figure shows a bottom view of the rod mount The 1 2 inch diameter rod hole is indicated in the photo Figure 3 Rod Mount Bottom View The following figure shows a side view of the r...

Страница 13: ...re longer rod lengths to ensure the endpoint is well supported and remains vertical 4 Without touching the meter body or adjacent pipes position the rod as close to the center of the pit as possible a...

Страница 14: ...the rod making sure the rod is completely seated into the Rod Mount hole of the endpoint The endpoint should slide freely onto the rod it should not be forced 7 When the installation is complete the e...

Страница 15: ...Mount Installation Water Solutions 60WP Endpoint Installation Guide 15 CAUTION If the endpoint module installation is too high too low or touching any of the surrounding surfaces then adjust as necess...

Страница 16: ...ead screw that is appropriate for the type of box material Installing Using a Wall Mount To install the 60WP Endpoint using the wall mount method mount the endpoint on the pit box wall so that the top...

Страница 17: ...oint housing 6 Keeping the 60WP endpoint in the upright position drill the second pilot hole using the bottom mounting hole as a template NOTE If using a screw anchor mark the location of the bottom a...

Страница 18: ...t Lids with Holes This section describes how to install the 60WP Endpoint in a pit lid that already has a 1 3 4 inch 1 7 8 inch or 2 inch hole in the lid The Pit Lid Mounting Kit or the Passive Radiat...

Страница 19: ...e diameter of the hole in the pit lid If the hole diameter is 1 3 4 inch an O ring spacer is not required 3 For 1 7 8 inch or 2 inch holes place the appropriate O ring spacer over the pit lid mounting...

Страница 20: ...Endpoint into the offset cavity A of the retainer clip or passive radiator antenna and push until it snaps into place The finished assembly is shown below Installing Through New Lid This section descr...

Страница 21: ...n part number CFG 0771 006 Cable tie gun NOTE The pit lid mounting kit is not intended for applications involving vehicular traffic The passive radiator antenna should be used in incidental traffic ar...

Страница 22: ...s size hole You can discard the O rings 4 Insert the retainer clip or passive radiator antenna into the hole in the pit lid 5 From the underneath side of the lid place the retainer clip collar around...

Страница 23: ...elf mount adaptor to mount the endpoint in a pit lid slot IMPORTANT The pit lid and slot must have the correct dimensions for the 60WP assembly to fit properly The following illustration and the accom...

Страница 24: ...lowing tools and hardware are required when installing the 60WP Endpoint using a shelf mount adaptor for a pit lid slot Shelf Mount Adapter Itron part number CFG 0771 007 A Foam spacers To install usi...

Страница 25: ...assembly into the pit lid with the foam spacers positioned on each side of the pit lid slot Figure 6 Correct Position With Foam Spacers on Each Side of Slot A Correct position for foam spacers IMPORT...

Страница 26: ...7 Wrong Position for Spacers Spacers are not supported A Unsupported foam spacer 4 The installed position of the endpoint should be vertical and upright when the lid is replaced on the pit IMPORTANT...

Страница 27: ...inline connector assembly Follow the manufacturer s recommended procedure for installing the water meter register on the meter To connect the inline connector NOTE Skip this step if an inline connecto...

Страница 28: ...install the endpoint Any of the three pins are damaged or missing The O ring is missing The cable is cut or nicked 2 Connect the endpoint to the register cable connector Holding the connectors by the...

Страница 29: ...curity seal after servicing either device To order more parts see the Water Endpoint Ordering Guide PUB 0063 001 IMPORTANT Be sure to protect connectors with protective covers Do not leave an exposed...

Страница 30: ...White G Black R Using an Extended Cable If you need to extend the length of the existing endpoint cable up to a maximum of 300 feet additional cable can be ordered from Itron For cable lengths exceed...

Страница 31: ...ndlheld device Activating Programming Mode Use the programming magnet Itron part number MLD 0175 001 to place the endpoint into Programming Mode Place the magnet on top of the Rod Mount Hole A as show...

Страница 32: ...aced in the Quite Mode For more information see Operating Modes on page 8 Programming the 60WP Endpoint To program a 60WP Endpoint use an FC200SR handheld running the Itron Endpoint Link or Endpoint L...

Страница 33: ...ing the 60WP Endpoint Water Solutions 60WP Endpoint Installation Guide 33 The correct position for programming the endpoint is shown below Figure 12 Programming the 60WP Correct Position for Handheld...

Страница 34: ...dheld computers to verify consumption G5R FC200R FC200SR NOTES Each handheld radio requires special setup and configuration parameters to successfully read and program 60 series products Refer to the...