1. INTRODUCTION 

This manual is a guide to the correct use of the display VA-1. 

This set has been specially designed to accomplish with the ITC “MIE-AEM-2” regulation for lifting and 

maintenance equipment, referring to tower cranes in constructions or other applications. 

This  device  reads  through  the  RS485  cable  the  information  sent  by  the  ITOWA  anemometer  and  it 

has been designed to display the instant speed of wind (fig 1). When the wind reaches 50 km/h,  the 

display  activates  one  relay  (

AV

)  and  the  notice  led  (Aviso).  When  the  wind  reaches  70  km/h,  the 

display activates one relay (

AL

)  and the warning led (Alarma). (Figure 3 and Figure 1 respectively) 

 

 

 

   

 

 

 

 

A connection RS485  to an  anemometrical sensor ITOWA is  allowed, by realizing  an  initial test. This 

means  that  all  the  displays  are  connected  and  all  the  relays  are  activated  during  4  seconds.  The 

connection  type  will  be  automatically  selected  (RS485  or  Sensor).  In  case  it  did  not  detect  any 

c

onnection during 12 seconds, the message failure “Er. 6” (see attached table of display messages) 

would appear and the relays of notice 

AV

 (aviso) and warning 

AL

 (alarma) would be activated.  

Whenever  there  is  a  wrong  connection  or  a  break  of  any  cables  of  the  sensor,  the  display  shows 

message “Er 5” (see attached table of display messages) and the notice 

AV

 relay blinks. 

Figure 2 

Figure 3 

Figure 1 

Brown (GND) 

+10 Vdc 

White 

Green (Pulses) 