6.4. BATTERY CHARGING

 

The batteries supplied with ITOWA equipment do not have a memory effect, meaning that they can be 

charged  without  having  to  be  totally  flat.    Therefore,  in  order  to  lengthen  their  life  span,  it  is 
recommended to use one battery every half day of work. 

7. DISPLAYING THE CODE 
7.1. DISPLAYING THE CODE OF THE SET 

If you want to know the code of the set, the receiver can display it by turning on jumper J1 of the base 
plate.  
To start displaying, place the jumper in the position indicated in the following figure:

 

 

 

 

 

 

 

 

The  presentation  sequence  of  the  code  will  start  through  the  LEDS.    The  hexadecimal  value  of  each 

group will be represented by a LED of the front panel of the receiver through a number of flashes equal 
to this value, starting with LED S1 with the first digit of the code (reading from left to right). 

The  following  table  shows  the  correspondence  between  the  hexadecimal  value  of  each  digit  and  the 
number of flashes corresponding to the LED it represents. 

 

Code carácter (Hexadecimal value)

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

A

 

B

 

C

 

D

 

E

 

F

 

Number of pulses (Decimal value)

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

Bear in mind that once the receiver detects the position of jumper J1, the test of all the LEDs is carried 
out  without  interruption.    Between  the  presentation  of  one  LED  and  another,  all  the  LEDs  flash  as  a 
separation  mark.    If  the  position  of  Jumper  J1  is  changed  during  the  test,  the  sequence  is  not 

interrupted.  For better understanding of this process, an example of the code and the resulting display 
is given. The code of the example is: 01A38E 

 

Led

 

S1

 

S2

 

S3

 

S4

 

 

 

Code

 

0

 

1

 

A

 

3

 

8

 

E

 

Number of pulses

 

0

 

1

 

10

 

3

 

8

 

14

 

VA001228 

Содержание TUNNER SETS

Страница 1: ...ItowaK USER MANUAL TUNNER SETS GCFI...

Страница 2: ......

Страница 3: ...UTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITOWA RESEREVESTHERIGHTTOMODIFYTHISMANUALWITHOUTP...

Страница 4: ...1 FASTENING OPTIONS 7 5 2 CONNECTING THE SET 8 5 3 POWERSUPPLYOFTHERECEIVER 8 5 4 START UP 8 5 4 1 SETTING THE TRANSMISSION TIME 8 5 4 2 BATTERY STATUS 9 6 MAINTENANCE OF THE RADIOCONTROL SET 9 6 1 MA...

Страница 5: ...ItowaK TUNNER SETS USER MANUAL...

Страница 6: ...ItowaK TUNNER SETS USER MANUAL FULLY CHARGE THE BATTERIES BEFORE USING THE SET FOR THE FIRST TIME...

Страница 7: ...If this is not possible he should position himself where he can see as much of the manoeuvre as possible and coordinate with another person when he cannot see properly Never perform a manoeuvre which...

Страница 8: ...rnatively 3 DESCRIPTION OF THE SET TRANSMITTER RECEIVER BATTERIES CHARGER 3 1 TRANSMITTER This is a sealed pushbutton box in highly resistant plastic material The manoeuvre pushbuttons and display led...

Страница 9: ...noeuvre of the crane The signal received by the antenna is injected into the receiver which supplies a low frequency signal in FFSK code to the microprocessor The control module checks that the inform...

Страница 10: ...play leds one for power supply indicating that the set is connected to the mains and the other indicating that the battery is being charged When the battery is inserted the charger tests its level and...

Страница 11: ...SIVE EMERGENCY TIME 1900 ms RADIUS OF ACTION 90 metres Frequency bands 433 050 to 434 775 MHz I ETS 300 220 868 000 to 870 000 MHz TEMPERATURE RANGE From 20 C to 70 C Transmission power 10 mW P R A Po...

Страница 12: ...cording to EN 60047 5 1 Max consumption 0 1 A 48 Vac 0 05 A 115 Vac 0 03 A 230 Vac 0 135 A 24 Vdc Connection By means of an Itowa 26 pin connector Fuses Emergency Stop Manoeuvre 3 A Dimensions Externa...

Страница 13: ...antenna it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS Standard fixing 1 2 Optional fixing For the magnetic fas...

Страница 14: ...STOP BUTTON and press the START button the remote control will start to operate by turning on the stop and start relays and the general contactor will be locked The led and the S1 led Start up led of...

Страница 15: ...have purchased is manufactured using top quality materials to ensure perfect working order and operation of the remote control Similarly to all machinery and equipment the remote control requires mini...

Страница 16: ...d passive safety circuits The correct working order of all the leds display messages The receiver cover and packing gland should be properly sealed The firm fastening of the whole unit If the antenna...

Страница 17: ...ugh a number of flashes equal to this value starting with LED S1 with the first digit of the code reading from left to right The following table shows the correspondence between the hexadecimal value...

Страница 18: ...check that all actuators of the transmitter are in the stand by position Led S4 of the RX flashes Eeprom fault Check in the RX that it is inserted in its housing If it is and still does not work conta...

Страница 19: ...n of set for time or STOP BUTTON MODE S2 Stand by mode or manoeuvre without changes Fault in Stop relays Flash for each mode change in one of the relays MODE S3 MODE S4 E2p Ok Error in eeprom MODE Set...

Страница 20: ...S MODE Transmitter on Communication between Tx Rx Together with led keypad Transmitter off MODE S1 E2prom error MODE S2 Manoeuvre button is on when start button is pressed MODE Standby mode or battery...

Страница 21: ...anoeuvre does not require independent contacts a jumper should be made between terminals 23 and 25 and the manoeuvre in terminals 24 and 26 should be connected This relay can be configured as N C thro...

Страница 22: ...nic waste separately means avoiding possible negative consequences on the environment and also the materials can be treated and recycled leading to significant saving in energy and resources To underl...

Страница 23: ......

Отзывы: