Itowa TUNNER SETS Скачать руководство пользователя страница 1

 
 
 
 

 

ItowaK 

 
 
 
 
 
 
 
 

 

USER MANUAL

 

 

TUNNER SETS

 

GCFI

 

Содержание TUNNER SETS

Страница 1: ...ItowaK USER MANUAL TUNNER SETS GCFI...

Страница 2: ......

Страница 3: ...UTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITOWA RESEREVESTHERIGHTTOMODIFYTHISMANUALWITHOUTP...

Страница 4: ...1 FASTENING OPTIONS 7 5 2 CONNECTING THE SET 8 5 3 POWERSUPPLYOFTHERECEIVER 8 5 4 START UP 8 5 4 1 SETTING THE TRANSMISSION TIME 8 5 4 2 BATTERY STATUS 9 6 MAINTENANCE OF THE RADIOCONTROL SET 9 6 1 MA...

Страница 5: ...ItowaK TUNNER SETS USER MANUAL...

Страница 6: ...ItowaK TUNNER SETS USER MANUAL FULLY CHARGE THE BATTERIES BEFORE USING THE SET FOR THE FIRST TIME...

Страница 7: ...If this is not possible he should position himself where he can see as much of the manoeuvre as possible and coordinate with another person when he cannot see properly Never perform a manoeuvre which...

Страница 8: ...rnatively 3 DESCRIPTION OF THE SET TRANSMITTER RECEIVER BATTERIES CHARGER 3 1 TRANSMITTER This is a sealed pushbutton box in highly resistant plastic material The manoeuvre pushbuttons and display led...

Страница 9: ...noeuvre of the crane The signal received by the antenna is injected into the receiver which supplies a low frequency signal in FFSK code to the microprocessor The control module checks that the inform...

Страница 10: ...play leds one for power supply indicating that the set is connected to the mains and the other indicating that the battery is being charged When the battery is inserted the charger tests its level and...

Страница 11: ...SIVE EMERGENCY TIME 1900 ms RADIUS OF ACTION 90 metres Frequency bands 433 050 to 434 775 MHz I ETS 300 220 868 000 to 870 000 MHz TEMPERATURE RANGE From 20 C to 70 C Transmission power 10 mW P R A Po...

Страница 12: ...cording to EN 60047 5 1 Max consumption 0 1 A 48 Vac 0 05 A 115 Vac 0 03 A 230 Vac 0 135 A 24 Vdc Connection By means of an Itowa 26 pin connector Fuses Emergency Stop Manoeuvre 3 A Dimensions Externa...

Страница 13: ...antenna it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS Standard fixing 1 2 Optional fixing For the magnetic fas...

Страница 14: ...STOP BUTTON and press the START button the remote control will start to operate by turning on the stop and start relays and the general contactor will be locked The led and the S1 led Start up led of...

Страница 15: ...have purchased is manufactured using top quality materials to ensure perfect working order and operation of the remote control Similarly to all machinery and equipment the remote control requires mini...

Страница 16: ...d passive safety circuits The correct working order of all the leds display messages The receiver cover and packing gland should be properly sealed The firm fastening of the whole unit If the antenna...

Страница 17: ...ugh a number of flashes equal to this value starting with LED S1 with the first digit of the code reading from left to right The following table shows the correspondence between the hexadecimal value...

Страница 18: ...check that all actuators of the transmitter are in the stand by position Led S4 of the RX flashes Eeprom fault Check in the RX that it is inserted in its housing If it is and still does not work conta...

Страница 19: ...n of set for time or STOP BUTTON MODE S2 Stand by mode or manoeuvre without changes Fault in Stop relays Flash for each mode change in one of the relays MODE S3 MODE S4 E2p Ok Error in eeprom MODE Set...

Страница 20: ...S MODE Transmitter on Communication between Tx Rx Together with led keypad Transmitter off MODE S1 E2prom error MODE S2 Manoeuvre button is on when start button is pressed MODE Standby mode or battery...

Страница 21: ...anoeuvre does not require independent contacts a jumper should be made between terminals 23 and 25 and the manoeuvre in terminals 24 and 26 should be connected This relay can be configured as N C thro...

Страница 22: ...nic waste separately means avoiding possible negative consequences on the environment and also the materials can be treated and recycled leading to significant saving in energy and resources To underl...

Страница 23: ......