Itowa ITW 4 LEVEL Скачать руководство пользователя страница 5

ITW LEVEL 

 

 

USER MANUAL

 

 

 

1. INTRODUCTION 

 

The manual you have is a guide to install correctly and make the start-up of the LEVEL ITW 
range.  These  equipments  are  specially  designed  for  the  wireless  Remote  Control  and 
teleprocessing. FM frequency and 2-GFSK codification are used for the radio transmission. 
The  most  advanced  technology  and  the  latest  generation  of  microprocessors  have  been 
incorporated in the electronic design, which allows a total safety of use. 
 
The  range  of  LEVEL  ITW  systems  are  operating  in  the  UHF  band  using  the  frequencies  
406MHz and 411MHz or in the frequency band  869MHz with 500 mW (p.r.a.) of maximum 
apparent radiated power and 25KHz of channelling (optionally 12,5KHz of channelling) 

 

The ITW LEVEL range is composed by the following sets: 

 
•   ITW 4 LEVEL of  4 digital signals  
 
•   ITW 8 LEVEL of  8 digital  
 
•   ITW 4A 4D LEVEL of 4 digital and 4 analogical signals  

 

•   ITW 4A 4D LEVEL of 8 digital and  4 analogical signals  
 
230Vac power supply and optionally at 12Vdc 
 
 
 
 
 
 

 

 

Содержание ITW 4 LEVEL

Страница 1: ...LEVEL ITW USER MANUAL USER MANUAL LEVEL ITW SET...

Страница 2: ...RIOR WRITTEN AUTHORIZATION FROM SINDITO SL IN THE EVENT OF INFRINGEMENT SINDITO S L RESERVES THE RIGHT TO UNDERTAKE THE ACTION IT DEEMS APPROPRIATE IN ACCORDANCE WITH THE CURRENTLAW SINDITO SL RESERVE...

Страница 3: ...7 2 4 START UP 8 3 ANTENNAS 9 3 1 ANTENNAS POSITIONING 10 3 1 1 LINK POINT TO POINT 10 3 1 2 LINK BETWEEN VARIOUS POINTS 11 3 2 CONNECTION DIAGRAM OF THE ANTENNA WITH THE COAXIAL CABLE 12 4 GUIDE OF...

Страница 4: ...LEVEL ITW USER MANUAL...

Страница 5: ...incorporated in the electronic design which allows a total safety of use The range of LEVEL ITW systems are operating in the UHF band using the frequencies 406MHz and 411MHz or in the frequency band...

Страница 6: ...to that input that means the digital input n 1 corresponds to the relay output n 1 the input n 2 with the relay output n 2 and thus to complete all the signals In models with analogical signals in eac...

Страница 7: ...pe of set Equipment code and Frequency band Equipment code and Work channel Status of the digital inputs in the TRANSMITTER The status change of the inputs is not automatically refreshed in the LCD me...

Страница 8: ...y on the screen To refresh the information a new display sequence must be performed ERROR messages o ANALOGICAL INPUT OR OUTPUT NOT CONNECTED OR BELOW RANGE An analogical input or output not connected...

Страница 9: ...s that allow fixing it to a wall or at any other element with screws and studs NOTICE WHEN RAISING THE TOP BE SPECIALLY CAREFUL WITH THE CONNECTION HOSE OF THE MOTHER BOARD TO THE DISPLAY CIRCUIT LEDS...

Страница 10: ...ITW LEVEL USER MANUAL 6 POWER SUPLY Connection INPUT connection...

Страница 11: ...NNECTED The system is designed to be easily and quickly installed It is recommended to install the equipment in a place protected from the unpleasant weather as well as to place it in a fixed place To...

Страница 12: ...e signals from the transmitter is received correctly that the appropriate relays and led are activated on the receiver NOTICE CAUTION THE EQUIPMENT MUST NOT BE STARTED WITHOUT THE CORRESPONDING ANTENN...

Страница 13: ...y the customer it is chosen the most appropriated antenna to cover the indicated distances of link and the orographic characteristics of the zone The main characteristics of the antennas supplied with...

Страница 14: ...ITW LEVEL USER MANUAL 10 3 1 ANTENNAS POSITIONING 3 1 1 LINK POINT TO POINT TRANSMITTER TANKS LINK...

Страница 15: ...ITW LEVEL USER MANUAL 11 3 1 2 LINK BETWEEN VARIOUS POINTS...

Страница 16: ...ITW LEVEL USER MANUAL 12 3 2 CONNECTION DIAGRAM OF THE ANTENNA WITH THE COAXIAL CABLE RG 213...

Страница 17: ...frequency matching with other systems SOLUTION Make the change of frequency channel REASON Misguided antennas SOLUTION Put the antennas in a new direction REASON Antennas not suitable for this link S...

Страница 18: ...YOU MUST MAKE SURE TO ASSIGN THE CORRECT FREQUENCY BAND ACCORDING TO THE RADIO MODEL OF YOUR SYSTEM The change of frequency can be done indistinctly when the system is working or without power It is r...

Страница 19: ...MHz band or vice versa the system WON T work WORKING CHANNEL The change of the working channel is done through a rotary switch of 10 positions 0 9 Each position has assigned a definite working channe...

Страница 20: ...en 406 MHz 411 MHz 869 MHz Channelling 25 KHz or 12 5 KHz Communication unidirectional to a single frequency Power from 0 2W till 2W depending of the band Harmonic Attenuation best than 70 dB Non esse...

Страница 21: ...t 1 led for reception 1 led for incidence 1 led On Presentation polyamide box with 30 fiberglass size 250 195 100 mm 6 2 GENERAL SPECIFICATIONS FOR 8 DIGITAL LEVEL ITW TRANSMITTER Power 230 Vac or 12...

Страница 22: ...20mA 0 5V 0 10V LCD Display inputs outputs and Presentation polyamide box with 30 fiberglass size 250 195 100 mm 6 4 GENERAL SPECIFICATIONS 4A8D DIGITAL ANALOGICAL LEVEL ITW TRANSMITTER Power 230 Vac...

Страница 23: ...t to leave the equipment unnecessarily exposed to the sun ATTENTION ORIGINAL SPARE PARTS SHOULD BE USED FOR ALL REPAIRS AND UNDER ANY CONCEPT THE SAFETY CHARACTERISTICS OF THE EQUIPMENT MUST BE CHANGE...

Страница 24: ...rom the general refuses avoids possible negative consequences to environment it allows the treatment and recycle of all the components obtaining important energy and resources savings To underline the...