Itowa ITW 4 LEVEL Скачать руководство пользователя страница 18

ITW LEVEL 

 

 

USER MANUAL

 

14 

 

 

5

. CHANGE OR FREQUENCY  

In  case  that  the system  does  not  link correctly  due  to  the  interferences  in  the  programmed 
frequency band, the working channel can be changed manually.  
 
 
 

NOTICE: 

THE  CHANGE  OF  WORKING  CHANNEL  MUST  BE  DONE  IN  THE 

TRANSMITTER AND IN THE RECEIVER. 
YOU MUST MAKE SURE TO ASSIGN THE CORRECT FREQUENCY BAND 
ACCORDING TO THE RADIO MODEL OF YOUR SYSTEM.  

 

 

 

 
The  change  of  frequency  can  be  done  indistinctly,  when  the  system  is  working  or  without 
power. 
 
It is recommended to start the change of frequency on the receiver system and after on the 
transmitter. In case that the systems were working, the change will be done after 10 seconds 
approximately. 
  
To  make  the  change  you  must  open  the  system  and  to  log  into  the  changing  frequency 
control board. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ITW 4 LEVEL

Страница 1: ...LEVEL ITW USER MANUAL USER MANUAL LEVEL ITW SET...

Страница 2: ...RIOR WRITTEN AUTHORIZATION FROM SINDITO SL IN THE EVENT OF INFRINGEMENT SINDITO S L RESERVES THE RIGHT TO UNDERTAKE THE ACTION IT DEEMS APPROPRIATE IN ACCORDANCE WITH THE CURRENTLAW SINDITO SL RESERVE...

Страница 3: ...7 2 4 START UP 8 3 ANTENNAS 9 3 1 ANTENNAS POSITIONING 10 3 1 1 LINK POINT TO POINT 10 3 1 2 LINK BETWEEN VARIOUS POINTS 11 3 2 CONNECTION DIAGRAM OF THE ANTENNA WITH THE COAXIAL CABLE 12 4 GUIDE OF...

Страница 4: ...LEVEL ITW USER MANUAL...

Страница 5: ...incorporated in the electronic design which allows a total safety of use The range of LEVEL ITW systems are operating in the UHF band using the frequencies 406MHz and 411MHz or in the frequency band...

Страница 6: ...to that input that means the digital input n 1 corresponds to the relay output n 1 the input n 2 with the relay output n 2 and thus to complete all the signals In models with analogical signals in eac...

Страница 7: ...pe of set Equipment code and Frequency band Equipment code and Work channel Status of the digital inputs in the TRANSMITTER The status change of the inputs is not automatically refreshed in the LCD me...

Страница 8: ...y on the screen To refresh the information a new display sequence must be performed ERROR messages o ANALOGICAL INPUT OR OUTPUT NOT CONNECTED OR BELOW RANGE An analogical input or output not connected...

Страница 9: ...s that allow fixing it to a wall or at any other element with screws and studs NOTICE WHEN RAISING THE TOP BE SPECIALLY CAREFUL WITH THE CONNECTION HOSE OF THE MOTHER BOARD TO THE DISPLAY CIRCUIT LEDS...

Страница 10: ...ITW LEVEL USER MANUAL 6 POWER SUPLY Connection INPUT connection...

Страница 11: ...NNECTED The system is designed to be easily and quickly installed It is recommended to install the equipment in a place protected from the unpleasant weather as well as to place it in a fixed place To...

Страница 12: ...e signals from the transmitter is received correctly that the appropriate relays and led are activated on the receiver NOTICE CAUTION THE EQUIPMENT MUST NOT BE STARTED WITHOUT THE CORRESPONDING ANTENN...

Страница 13: ...y the customer it is chosen the most appropriated antenna to cover the indicated distances of link and the orographic characteristics of the zone The main characteristics of the antennas supplied with...

Страница 14: ...ITW LEVEL USER MANUAL 10 3 1 ANTENNAS POSITIONING 3 1 1 LINK POINT TO POINT TRANSMITTER TANKS LINK...

Страница 15: ...ITW LEVEL USER MANUAL 11 3 1 2 LINK BETWEEN VARIOUS POINTS...

Страница 16: ...ITW LEVEL USER MANUAL 12 3 2 CONNECTION DIAGRAM OF THE ANTENNA WITH THE COAXIAL CABLE RG 213...

Страница 17: ...frequency matching with other systems SOLUTION Make the change of frequency channel REASON Misguided antennas SOLUTION Put the antennas in a new direction REASON Antennas not suitable for this link S...

Страница 18: ...YOU MUST MAKE SURE TO ASSIGN THE CORRECT FREQUENCY BAND ACCORDING TO THE RADIO MODEL OF YOUR SYSTEM The change of frequency can be done indistinctly when the system is working or without power It is r...

Страница 19: ...MHz band or vice versa the system WON T work WORKING CHANNEL The change of the working channel is done through a rotary switch of 10 positions 0 9 Each position has assigned a definite working channe...

Страница 20: ...en 406 MHz 411 MHz 869 MHz Channelling 25 KHz or 12 5 KHz Communication unidirectional to a single frequency Power from 0 2W till 2W depending of the band Harmonic Attenuation best than 70 dB Non esse...

Страница 21: ...t 1 led for reception 1 led for incidence 1 led On Presentation polyamide box with 30 fiberglass size 250 195 100 mm 6 2 GENERAL SPECIFICATIONS FOR 8 DIGITAL LEVEL ITW TRANSMITTER Power 230 Vac or 12...

Страница 22: ...20mA 0 5V 0 10V LCD Display inputs outputs and Presentation polyamide box with 30 fiberglass size 250 195 100 mm 6 4 GENERAL SPECIFICATIONS 4A8D DIGITAL ANALOGICAL LEVEL ITW TRANSMITTER Power 230 Vac...

Страница 23: ...t to leave the equipment unnecessarily exposed to the sun ATTENTION ORIGINAL SPARE PARTS SHOULD BE USED FOR ALL REPAIRS AND UNDER ANY CONCEPT THE SAFETY CHARACTERISTICS OF THE EQUIPMENT MUST BE CHANGE...

Страница 24: ...rom the general refuses avoids possible negative consequences to environment it allows the treatment and recycle of all the components obtaining important energy and resources savings To underline the...

Отзывы: