ITI SuperBus 8Z Скачать руководство пользователя страница 3

SuperBus 8Z LED Touchpad

Page 3

6.

Position the mounting plate in its normal mount-
ing position (tab at the bottom) and fold the card 
toward you at all three scored lines. The “Zones” 
section should be facing you and the folds should 
create a tab to slide the card in and out.

7.

Align the mounting plate wall-mount holes with 
the wall anchors and secure the back plate to the 
wall using the screws provided.

or-- If installing the backplate on an electrical gang

box, line up the appropriate gang box holes on the
mounting plate with the gang box holes and
secure the back plate to the gang box using the
screws provided.

Note:

Do not overtighten screws or the back plate 
may bind and prevent the touchpad from 
mounting properly.

8.

For wall-mounted installations, cut a hole in the 
wall in the wire access area of the mounting plate 
to pull your cable through for wiring.

Wiring

Wiring consists of connecting the touchpad to the 
panel terminals.

Wiring the Touchpad to Concord Panels

1.

Disconnect the panel’s transformer and backup 
battery.

2.

Run a 4-conductor, 18- to 22-gauge wire from the 
panel to the touchpad location.

3.

Splice the 4-conductor cable wires to the red, 
black, green, and white wires located on the back 
of the touchpad.

4.

Connect the touchpad wiring to the panel termi-
nals as shown in Figure 4

Figure 4. Wiring the Touchpad to Concord Panels

Setting the Touchpad’s Device Address

Before powering up the panel, the touchpad’s DIP 
switches must be set to a device address different from 
all other bus devices to ensure correct operation and 
avoid bus conflicts. In most installations, the default 
setting of 3 (both DIP switches on) should work.

Use the following guidelines to avoid communication 
conflicts between bus devices and the panel:

O

All bus devices with address DIP switches (LED 
Touchpad, ESM, HIM, etc.) must be set to the 
desired address before applying power and 
entering the program mode.

O

Whenever possible, assign touchpad addresses 
before all other panel programming.

To set the touchpad’s unit number:

1.

Locate the DIP switches on the back of the touch-
pad, at the upper-left corner.

2.

Set the DIP switches to an address different from 
all other bus devices connected to the panel. Fig-
ure 5 shows the possible touchpad unit number 
settings.

8581G05A.DSF

3

4

5

6

+12V

RED

BUS A

GREE

N

BUS B

WH

IT

E

GND

BLACK

PANEL
TERMINALS

+12V

BUS

BUS A

BUS B

GND

TOUCHPAD WIRES