6.
Position the mounting plate in its normal mount-
ing position (tab at the bottom) and fold the card
toward you at all three scored lines. The “Zones”
section should be facing you and the folds should
create a tab to slide the card in and out.
7.
Align the mounting plate wall-mount holes with
the wall anchors and secure the back plate to the
wall using the screws provided.
or-- If installing the backplate on an electrical gang
box, line up the appropriate gang box holes on the
mounting plate with the gang box holes and
secure the back plate to the gang box using the
screws provided.
Note:
Do not overtighten screws or the back plate
may bind and prevent the touchpad from
mounting properly.
8.
For wall-mounted installations, cut a hole in the
wall in the wire access area of the mounting plate
to pull your cable through for wiring.
Wiring
Wiring consists of connecting the touchpad to the
panel terminals.
Wiring the Touchpad to Concord Panels
1.
Disconnect the panel’s transformer and backup
battery.
2.
Run a 4-conductor, 18- to 22-gauge wire from the
panel to the touchpad location.
3.
Splice the 4-conductor cable wires to the red,
black, green, and white wires located on the back
of the touchpad.
4.
Connect the touchpad wiring to the panel termi-
nals as shown in Figure 4
Figure 4. Wiring the Touchpad to Concord Panels
Setting the Touchpad’s Device Address
Before powering up the panel, the touchpad’s DIP
switches must be set to a device address different from
all other bus devices to ensure correct operation and
avoid bus conflicts. In most installations, the default
setting of 3 (both DIP switches on) should work.
Use the following guidelines to avoid communication
conflicts between bus devices and the panel:
O
All bus devices with address DIP switches (LED
Touchpad, ESM, HIM, etc.) must be set to the
desired address before applying power and
entering the program mode.
O
Whenever possible, assign touchpad addresses
before all other panel programming.
To set the touchpad’s unit number:
1.
Locate the DIP switches on the back of the touch-
pad, at the upper-left corner.
2.
Set the DIP switches to an address different from
all other bus devices connected to the panel. Fig-
ure 5 shows the possible touchpad unit number
settings.
8581G05A.DSF
3
4
5
6
+12V
RED
BUS A
GREE
N
BUS B
WH
IT
E
GND
BLACK
PANEL
TERMINALS
+12V
BUS
BUS A
BUS B
GND
TOUCHPAD WIRES