ITI 60-755 Скачать руководство пользователя страница 3

Power Line Carrier Card

Page 3

Troubleshooting

Table 1 describes problems you may experience 
after connecting devices to your panel. Possible 
solutions are listed in the Cause/Action column. 

Specifications

Compatibility: 

Concord Hybrid Control Panel 

Concord RF16 Wireless Control Panel

Power Requirements: 

Input Voltages:

+5 and +12 VDC

Output Voltages: 4.2 V, peak to peak, across 

5 ohm load

Current Draw:

Nominal = 110 mA
Idle = 10 µA

Dimensions:

2.95” x 1.95” x.875”
(7.49 x 4.95 x 2.22 cm)

Operating Temperature

10° to 120° F 
(0° to 50° C)

Table 1. Troubleshooting

Problem

Cause/Action

The light or siren will not 
work.

1. The power transformer is 
not line carrier compatible. 
Replace it with a Power 
Line Carrier Transformer 
(60-672 or 60-779).

2. The house code is not 
programmed into the panel, 
ITI Supervised Wireless 
Sirens, or X-10 modules.
 
Verify that the proper house 
code is entered for all com-
ponents. Program the proper 
house code if necessary.

3. Power Line Carrier isn’t 
seated correctly.
 Remove 
the card and gently press it 
back onto the panel circuit 
board.