Power Line Carrier Card
Page 3
Troubleshooting
Table 1 describes problems you may experience
after connecting devices to your panel. Possible
solutions are listed in the Cause/Action column.
Specifications
Compatibility:
■
Concord Hybrid Control Panel
■
Concord RF16 Wireless Control Panel
Power Requirements:
■
Input Voltages:
+5 and +12 VDC
■
Output Voltages: 4.2 V, peak to peak, across
5 ohm load
■
Current Draw:
Nominal = 110 mA
Idle = 10 µA
■
Dimensions:
2.95” x 1.95” x.875”
(7.49 x 4.95 x 2.22 cm)
■
Operating Temperature
10° to 120° F
(0° to 50° C)
Table 1. Troubleshooting
Problem
Cause/Action
The light or siren will not
work.
1. The power transformer is
not line carrier compatible.
Replace it with a Power
Line Carrier Transformer
(60-672 or 60-779).
2. The house code is not
programmed into the panel,
ITI Supervised Wireless
Sirens, or X-10 modules.
Verify that the proper house
code is entered for all com-
ponents. Program the proper
house code if necessary.
3. Power Line Carrier isn’t
seated correctly. Remove
the card and gently press it
back onto the panel circuit
board.