Power Line Carrier Card
Page 2
Figure 1. Concord Hybrid Panel Circuit Board
Figure 2. Concord RF16 Wireless Panel Circuit Board
Figure 3. Power Line Carrier Card
Note:
You can discard the jumpers, unless you plan
to eventually remove the Power Line Carrier
Card.
4.
Insert the Power Line Carrier Card (see Figure 3)
solder side down and gently press into the panel
system board. (See either Figure 1 or Figure 2 for
the proper location of the Power Line Carrier
Card.)
5.
Reconnect the panel’s backup battery and AC
power transformer.
When the installation is complete, see the
“Testing” section of this manual.
Programming and Light Control
For complete programming information, refer to
the specific panel’s Installation Instructions or the
ITI Supervised Wireless Siren’s Installation
Instructions.
Testing
Test ITI Supervised Wireless Sirens by arming the
panel, disarming it, bypassing sensors, etc. Test
light control by turning lights on and off
individually, simultaneously, or through
programmed time schedules.
SNAP
CARD
HEADER
POWER LINE CARRIER
CARD HEADERS
BACKUP BATTERY
CONNECTIONS
TERMINAL STRIP
8615G03A.DSF
MICRO
PROCESSOR
PHONE LINE
– +
CARRIER CARD
SNAP CARD
HEADER
BACKUP BATTERY
CONNECTIONS
MICROPROCESSOR
PLC
CARD
–
POWER LINE CARRIER
CARD HEADERS
8615G04A.DSF
TERMINAL STRIP
ANTENNAE CONNECTORS
+
8615G01A.DSF