ITI 60-688-95 Скачать руководство пользователя страница 3

 Page 3

Testing the Sensor

1.

Set the panel to the dealer sensor test 
mode.

2.

Take the sensor and magnet to the desired 
mounting location, making sure to line up 
their alignment marks with each other.

3.

Trip the sensor by pulling the magnet 
away from the sensor.

4.

Listen for interior siren beeps to indicate 
how many rounds the panel receives from 
the sensor. You should hear 6 to 8 beeps.

Note: 

The Learn Mode Micro Door/Window Sen-

sor has a built-in power-saver feature that 
turns on automatically when the sensor is 
tripped more than once, within a 4-1/4 
minute time period.
When this feature is on, the sensor trans-
mits only half the usual number of data 
rounds when tripped. For example, you 
may hear only up to 4 data rounds instead 

of 6 to 8.
For accurate sensor test results, leave the 
sensor undisturbed in the closed (non-
alarm) condition for 5 minutes before trip-
ping it for testing. This gives the sensor 
enough time to turn off the feature.

Mounting the Sensor

After successful programming and testing are 
completed, mount the sensor and magnet with  
double-sided tape (included) as follows:

Note: 

You must use 3 pieces of the double-sided 

tape on the sensor as described in step 1, 
to ensure the sensor does not move or 
rock.

1.

Apply 3 of the four pieces of double-sided 
tape to the bottom of the sensor and mount 
the sensor at the desired location.

2.

Apply the remaining piece of double-sided 
tape to the bottom of the magnet and 

Отзывы: