ITI 60-688-95 Скачать руководство пользователя страница 2

Page 2

dealer sensor test, before permanently 
mounting it.

Mount the sensor within 100 feet of the 
panel.

Mount the sensor on the frame, and the 
magnet on the door, window, or drawer. If 
mounting on double doors, mount the sen-
sor on the least used door and the magnet 
on the other door.

Programming

The following steps describe the general guide-
lines for adding the sensor into panel memory. 
Refer to the specific panel installation instruc-
tions or reference manual for complete pro-
gramming details.
1.

Set the panel to the program mode.

2.

Proceed to LEARN SENSORS.

3.

Select the appropriate sensor group and 

sensor number assignments.

4.

When prompted by the panel to trip the 
sensor for learning, remove the sensor 
cover and slide the battery about half-way 
out of the battery holder (see Figure 1).

Figure 1. Slide Battery Out of Holder at 
Location and In Direction of Arrow

5.

Slide the battery back into the holder.

6.

Exit program mode.

7.

Place the cover back on the sensor.

8948g03a

Отзывы: