3.1.
Installation requirements
Please observe the following before installation: Mount
the BTV:
●
At a height of 2.3 metres above the ground in the wall, or in
the ceiling (not in the floor or in a sloping wall!).
●
In a room where there is sufficient supply air.
●
in the vicinity of a 230 V, 50 Hz wall socket.
Ensure low resistances by using as many short, straight and
smooth ducts as possible. When using flexibles, we recommend
using a larger duct diameter. Also use a wall duct with low
resistance.
The fan is suitable for a connection diameter of 100 mm.
Placement against a connection diameter up to 125 mm is
possible, but may slightly affect performance.
Warning!
When using a cable tray, a suitable power cable with an outer
diameter of 5 to 7 mm must be passed through the rubber cable
duct and strain relief provided.
Warning!
Before starting the electrical installation (connecting the
wiring), de-energise the group to which the fan is connected.
Do not re-energise the group until AFTER the installation has
been completed.
Warning!
Never connect the device with an extension lead!
Warning!
Never connect the device with a damaged power cable!
3.2.
Installing the fan
The bathroom toilet fan BTV-ssst should be mounted in the wall or
ceiling.
c) Drill the necessary holes for the plugs supplied. Use the rear
part of the fan itself as a marking template or use the
dimensional drawings.
Mount the fan as follows:
a)
Make sure that any remaining dirt is removed from the hole.
b)
Check whether there is a power supply connection at the
location where the fan is to be installed.
d)
Insert the supplied plugs.
Warning!
The duct to the outside must be leak-tight connected to the
fan and installed at a slope.
Warning!
The fan should discharge the exhaust air directly to the outside.