5. Use
5.1. Pairing
Proceed as follows to link the sensor to the ventilation
unit:
a) Set the ventilation unit to pairing mode as described
in the manual for the ventilation unit.
Then ensure that the sensor sends a pairing signal within 2
minutes. If pairing fails, repeat the procedure.
b) Restore power to the sensor by refitting the cover
with the circuit board.
All green LEDs flash three times when the sensor is
initialised. After this the status will be red.
c)
Hold the touch button down (5-7 seconds) until the
status LED is continuously lit
white
. At this point the
sensor sends a pairing message.
d) The pairing status is shown as follows:
-
Status LED flashes
green
(once per second):
pairing successful; RF signal level good. The
ventilation unit briefly changes speed to indicate
that pairing was successful.
-
Status LED flashes
orange
(once per second):
pairing successful; RF signal level moderate.
The ventilation unit briefly changes speed to
indicate that pairing was successful.
-
Status LED flashes
red
(once per second):
pairing failed.
If pairing fails, repeat the entire procedure from the
start.
e) When pairing is successful, the LEDs flash for five
seconds and then show the status and ventilation
speed of the ventilation unit.
f)
The sensor is now linked to the ventilation unit.