Measurement Commands
Copyright © Itech Electronic Co., Ltd.
12
MEASure:POWer?
FETCh:POWer?
This command is used to read the active power of WATT as the unit.
Command syntax:
MEASure[:SCALar]:POWer[:ACTive]?
FETCh[:SCALar]:POWer[:ACTive]?
Returned value:
<NR3>
MEASure:POWer:MAXimum?
FETCh:POWer:MAXimum?
This command is used to read the maximum input power value.
Command syntax:
MEASure[:SCALar]:POWer[:AMPLitude]:MAXimum?
FETCh[:SCALar]:POWer[:AMPLitude]:MAXimum?
Returned value:
<NR3>
MEASure:POWer:APParent?
FETCh:POWer:APParent?
This command is used to read the apparent power of VA as the unit.
Command syntax:
MEASure[:SCALar]:POWer:APParent?
FETCh[:SCALar]:POWer:APParent?
Returned value:
<NR3>