Returns
<CRD>
VOLTage|CURRent|EXTernal|BUS|MANual|IMMediate
TRIGger:ACQuire:VOLTage:SLOPe <CPD>
This command is used to set the voltage trigger edge of the Meter.
•
POSitive: Rising edge
•
NEGative: Falling edge
•
EITHer: Both rising and falling edges
Before executing this command, you need to set the trigger source of the
Meter function to voltage.
Group
TRIGger
Syntax
TRIGger:ACQuire:VOLTage:SLOPe <CPD>
Arguments
<CPD>
POSitive|NEGative|EITHer
Default Value
POSitive
Example
TRIGger:ACQuire:VOLTage:SLOPe NEGative
Query Syntax
TRIGger:ACQuire:VOLTage:SLOPe?
Copyright © Itech Electronic Co., Ltd.
64