![ITech GRN-45-1001 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/itech/grn-45-1001/grn-45-1001_programming-manual_2095317045.webp)
Source Commands
Copyright © Itech Electronic Co., Ltd.
24
Default value
0.025,0.100
Example
CURR:SLEW 0.030,0.030
Query command
[SOURce:]CURRent:SLEW[:BOTH]?
[MINimum|MAXimum],[MINimum|MAXimum]
Returns
<NR3>,<NR3>
[SOURce:]CURRent:SLEW:NEGative <NRf+>
This command sets the current falling slew rate of the power supply.
Syntax
[SOURce:]CURRent:SLEW:NEGative <NRf+>
Arguments
<0.025-9.999>
Default value
0.100S
Example
CURR:SLEW:NEG 1.000
Query command
[SOURce:]CURRent:SLEW:NEGative? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent:SLEW:POSitive <NRf+>
This command sets the current rising slew rate of the power supply.
Syntax
[SOURce:]CURRent:SLEW:POSitive <NRf+>
Arguments
<0.025-9.999>