![ITech GRN-45-1001 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/itech/grn-45-1001/grn-45-1001_programming-manual_2095317027.webp)
Output Commands
Copyright © Itech Electronic Co., Ltd.
6
Chapter4 Output Commands
OUTPut[:STATe] <bool>
This command sets the output state of the power supply.
Syntax
OUTPut[:STATe] <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
OUTP ON
Query command
OUTPut[:STATe]?
Returns
0|1
[OUTPut:]PROTection:CLEar
This command clears the protection status.
Syntax
[OUTPut:]PROTection:CLEar
Arguments
None
Default value
Not applicable
Example
PROT:CLE
Query command
None