SAFETY INSTRUCTIONS

Please read this manual carefully before turning on the ITEC MULTIPOWER. Keep it in a safe place 
where you can fi nd it easily for future reference. 

Train all personnel who will use the device regarding use and safety instructions especially.

Do not cover the ventilation shafts of the device by any means. If you mount it in a rack you have to ensure 
proper air circulation. Mounting the device in a closed wooden furniture is not permitted entirely.

You must use a grounded plug socket when charging or operating the device. Make sure the power 
cord is not damaged. Never disconnect the ground conductor of the power plug.

Make sure the voltage indications on the back of the device match those of the available power grid 
BEFORE plugging in the device.

Un-plug the device during thunderstorms or when not using the device for longer period of time.

In case of any of the following conditions, the device has to be checked by qualifi ed staff: 

Damage to the power cord or power plug.

Liquids or small objects have entered the case

The device does not operate a usual

The device was exposed to a strong impact

The case has been damaged

Storing the device in humid conditions, operating it in poring rain or near splashing
water could cause damage. 
Avoid exposing the device to temperatures above 50°C or humidity above 95%.

Do not try to open the device. There are no serviceable parts inside. In case of damage or problems 
always contact your dealer or the manufacturer.

Use a soft, dry cloth to clean the device. Do not use any cleaning agents or thinners. These could 
damage the case or enter the case. Un-plug the device before attempting to clean it.

CAUTION: 

 Professionals servicing the device have to switch it off fi rst and unplug the power cord.

Содержание MULTIPOWER 2x1000

Страница 1: ...MULTIPOWER MANUAL Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria Europe ...

Страница 2: ... while keeping noise levels low A series of protective features provides operation at highest possible security levels We assure you to have taken the right decision in purchasing an ITEC MULTIPOWER power out put stage State of the art technology is paired with best usability functionality focussed design small form factor and various valuable details Please read this manual carefully and follow t...

Страница 3: ...ice Un plug the device during thunderstorms or when not using the device for longer period of time In case of any of the following conditions the device has to be checked by qualified staff Damage to the power cord or power plug Liquids or small objects have entered the case The device does not operate a usual The device was exposed to a strong impact The case has been damaged Storing the device i...

Страница 4: ...nically symmetrised inputs XLR jack and screw clamp Switch to activate bridge mode All output connectors are implemented as pluggable terminals Ground lift switch Soft start power up delay for speakers Protective switch to prevent open circuit operation short circuit and overheating Protective switch to prevent direct current at the speaker output Mixing operation of the two inputs in bridge mode ...

Страница 5: ...emote power up is activated fuse is ok 3 LEVEL CONTROL for CHANNEL A and B 4 STATUS LEDs GREEN Signal an audio signal is being processed level control is open YELLOW High input levels limiter is active to prevent distortion RED Protective switch activated short circuit overheated etc REMARK Every ITEC MULTIPOWER power output stage ships with a transparent shield made from plexiglas and two screws ...

Страница 6: ...ay fuse 3 POWER SUPPLY AC OUT You can supply power to auxiliary devices like pre amplifiers wireless transmitters and playback devices via this socket These devices will also be powered on off together with the MULTIPOWER power output stage CAUTION Do not connect other power output stages via this socket The fuse is not designed for this load ...

Страница 7: ...ut 9 OUTPUT TERMINALS 100V only for 2x200T and 2x300T You can connect 100V speaker systems to these terminals see connectivity layout 10 LOW RESISTANCE OUTPUT TERMINALS You can connect low resistance speaker systems to these terminals see connectivity layout 11 OPERATION MONITORING Potential free contacts to monitor operation Circuit closed if MULTIPOWER is ready for operation For wiring see conne...

Страница 8: ...8 www itec audio com MULTIPOWER MULTIPOWER CONNECTING LOW RESISTANCE SPEAKERS 2 channel Mode Bridge Mode ...

Страница 9: ...www itec audio com 9 MULTIPOWER MULTIPOWER CONNECTING 100V SPEAKERS MULTIPOWER 2X200T 2X300T 2 channel Mode Alternatively 50 or 70 Bridge Mode Short circuit has to be wired ...

Страница 10: ...10 www itec audio com MULTIPOWER MULTIPOWER CONNECTING MONITORING SYSTEMS Individual Monitoring Monitoring System Circuit closed OK Bulk Monitoring Monitoring System Circuit closed OK ...

Страница 11: ...R INPUT MUTING REMOTE POWER ON OPTIONAL External Power 12V DC Input muted if power applied Input circuit electrically isolated using Opto cou pling External Power 12V DC Device ON if power applied Input circuit electrically isolated using relay ...

Страница 12: ...ion 0 05 Frequency Range 25 22000 Hz 80 20000Hz Distance Voltage to Noise 105 dB Dimensions 482 x 88 x 350 mm W x H x D 19 2 unit racks Weight 11 4 kg 15 3 kg 17 5 kg 18 5 kg 13 0 kg 16 9 kg Operating Temperature 5 to 55 Max Power Consumption 1200 W 1800 W 2600 W 3200 W 1200 W 1800 W Input Sensitivity 3 dB sym 1Veff Protective Switches DC Short Circuit Oscillating Temperature Cooling Temperature c...

Отзывы: