www.itec-audio.com
7
MICROPHONES
ITEC 5300 RADIO MICROPHONE SYSTEMS
3.2 ITEC WM-5320, rechargeable
IR DIODE (REAR)
LED BATTERY INDICATOR
GREEN = BATTERY OK
YELLOW = BATTERY WEAK
ON/OFF SWITCH
POWER LOCK
PULL OFF CAP, TURN BY 180°
AND PUT CAP BACK ON AGAIN
3.2.1 Replacement of the capsule
The capsule can be unscrewed for replacement. The microphone is equipped with an electret capsule as
standard. A dynamic capsule is available upon request.
3.2.2 Lithium ion battery
The WM 5320 has a lithium ion battery of type 18500. When charging, only use the original ITEC-HC 80 char-
ger. The external charging contacts enable charging by simply placing the microphone into the charging
station without having to remove the battery. However, changing the battery and charging the removed bat-
tery are also possible (keep a spare battery for long periods of use). The operating time with a fully charged
battery is approx. 10 – 12 hours.
Replacing the lithium ion battery:
Unscrew the microphone capsule. Remove the round contact plate by pressing the two catches. The lithium
ion battery can now be easily removed. Pay attention to correct polarity when inserting the replacement
battery. The plus pole (marked by a groove) is at the top.