General information 

 
The  ITE-XTRA  is  the  culmination  of  over  30  years  of  Leak  detector  manufacturing 
experience.  ITE is proud to present this tool as the most stable and sensitive negative 
corona leak detector ever made.  We have incorporated all of our experience, and years 
of customer feedback into this product, in the hope of providing our valued customers 
with the best of everything; price, performance and reliability. 
 
An  advanced  microprocessor  is  the  heart  of  this  unit.    Its  digital  signal  processing 
permits  better  management  of  the  circuitry  and  sensing  tip  signal  than  ever  before 
possible.  Additionally, the number of components used in the circuit is reduced nearly 40 
%, increasing reliability and performance.  The microprocessor monitors the sensing tip 
and battery voltage levels 4000 times per second, compensating for even the most minor 
fluctuations  in  signal.    This  translates  into  a  stable  and  dependable  tool  in  almost  any 
environment. 
 
Convenience features have been added to enhance the usability of the ITE-XTRA. Seven 
levels of sensitivity provide an increase of 64 times from level 1 to level 7.  Unique Tri-
color  led‟s  show  a  progressive  and  wide  ranging  leak  size  indications,  communicate  the 
sensitivity level, and provide a true voltage indication of battery power level.  A tactile 
keypad  controls  all  functions  of  operation.    A  revolutionary  new  case  design  gives  the 
user grip and control, and places the visual indicators in direct sight during use. 
 
Please take a few moments to read through the following pages, in order to understand 
and benefit from all the capabilities of your new ITE-XTRA.  We trust that you will be 
100 % satisfied with your new purchase.  If you have any questions or comments after 
reviewing the manual, please feel free to contact us. 
 

Features 

 

 

Microprocessor control, with advanced digital signal processing 

 

Tricolor visual display 

 

Seven (7) levels of sensitivity provide an increase of up to 64 x 

 

Tactile keypad controls 

 

Real time sensitivity adjustment 

 

Battery test function 

 

Battery voltage indication 

 

Certified to SAE J1627 for R134a, R12, R22 

 

Detects all halogenated refrigerants 

 

True mechanical pumping provides positive airflow through sensing tip 

 

Mute feature included 

 

Cordless and portable, operates on 2 „C‟-cell batteries 

Содержание ITE-XTRA

Страница 1: ...Europark Oost 24 Tel 32 3 766 02 02 E mail sales ite tools com 9100 Sint Niklaas Belgium Fax 32 3 766 10 67 1 ITE XTRA ...

Страница 2: ...formation 3 Features 3 Parts Controls 4 Getting started 4 Installing batteries 4 Operating features 5 Battery indicator 5 Automatic reset 6 Sensitivity adjustment 6 Alarm indications 7 Operating instructions 7 Operating tips 8 Applications 9 Maintenance 9 Replacement parts 10 Specifications 11 Warranty 11 Español 12 Français 20 Deutsch 29 ...

Страница 3: ...een added to enhance the usability of the ITE XTRA Seven levels of sensitivity provide an increase of 64 times from level 1 to level 7 Unique Tri color led s show a progressive and wide ranging leak size indications communicate the sensitivity level and provide a true voltage indication of battery power level A tactile keypad controls all functions of operation A revolutionary new case design give...

Страница 4: ...eference leak source Parts controls 1 Sensing tip 6 Audio mute 2 Tip protector 7 Sensitivity up 3 Power ON OFF 8 Sensitivity down 4 Battery test 9 LED leak indicators 5 Reset button 10 Flexible probe Getting started Installing batteries Remove the battery compartment door located on the bottom of the instrument by sliding up as shown below Install batteries positive polarity outwards towards batte...

Страница 5: ...on The constant power indicator allows the user to see the battery level at all times The LED will remain on whenever the unit is powered on It may appear as one of three colors See Fig 3 GREEN Battery voltage is normal sufficient for proper operation ORANGE Battery voltage is approaching the lower threshold for operation replace as soon as possible RED Battery voltage is below acceptable operatin...

Страница 6: ...unit automatically sets itself to ignore the level of refrigerant present at the tip Only a level or concentration greater than this will cause an alarm CAUTION Be aware that this feature will cause the unit to ignore any refrigerant present at turn on In other words with the unit off if you place the tip up to a known leak and switch the unit on no leak will be indicated RESET FEATURE Pressing th...

Страница 7: ...display will show the LED s red The number of LED s lit indicates the level See Fig 5 Level one lowest sensitivity is shown by the leftmost LED Counting from left levels 2 through 7 are indicated by the corresponding number of red LED s i e level 7 is shown by all LED s lit 2 Pressing the SENSITIVITY or SENSITIVITY key will change the sensitivity The keys can be pressed intermittently to change le...

Страница 8: ...e Orange one at a time Operating Instructions Operation 1 Switch the unit on by pressing the ON OFF key The display will illuminate with the reset indication Left LED green all others Orange for 2 seconds 2 Verify the battery level by observing the constant power indicator see above 3 Upon turn on the unit is set to sensitivity level 5 A rapid but steady beep rate will be heard If desired the sens...

Страница 9: ...32 3 766 02 02 E mail sales ite tools com 9100 Sint Niklaas Belgium Fax 32 3 766 10 67 9 6 If a full alarm occurs before the leak is pinpointed press the RESET key to reset the circuit to a zero reference as described above ...

Страница 10: ...mperatures below 15 C 59 F leaks may not be measurable since this pressure may not be reached 2 Take care not to contaminate the detector probe tip if the part being tested is contaminated If the part is particularly dirty or condensate moisture is present it should be wiped off with a dry shop towel or blown off with shop air No cleaners or solvents should be used since the detector may be sensit...

Страница 11: ... minimum shutting it off then waiting for the refrigerant to accumulate in the case for 10 minutes After such time insert the leak detector probe into the blower resistor block or condensate drain hole if no water is present or into the closest opening in the heating ventilation air conditioning case to the evaporator such as the heater duct or a vent duct If the detector alarms a leak apparently ...

Страница 12: ...tip protector Never use the unit without the protector in place Before using the unit always inspect the tip and protector to see that they are free of dirt and or grease To clean 1 Remove protector by grasping and pulling off tip 2 Clean protector with shop towel and or compressed air 3 If the tip itself is dirty it can be cleaned by immersing in a mild solvent such as alcohol for a few seconds a...

Страница 13: ...pped with one Carrying Case one Owner s Manual 2 C cell batteries and one replacement Sensing Tip and Protector To purchase replacement parts for your leak detector please contact your local distributor To ensure that you obtain the correct parts it is best to reference the part number when placing your order Replacement Parts ITE XTRA 2 Maintenance Kit 3 Sensing Tips 3 Tip Protectors ...

Страница 14: ...ured to provide unlimited service Should the unit be inoperative after performing the recommended maintenance a no charge repair or replacement will be made to the original purchaser if the claim is made within three years from the date of purchase This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use This warranty does not cover batte...

Отзывы: