Table of contents 

 
 
General information 

 
Features 

 
Parts & Controls 

 
Getting started 

 

Installing batteries 

 
Operating features 

 

Battery indicator 

 
Automatic reset 

 
Sensitivity adjustment 

 
Alarm indications 

 

Operating instructions 

 
Operating tips 

 
Applications 

 
Maintenance 

 
Replacement parts 

10 

 
Specifications 

11 

 
Warranty 

11 

 
Español 

12 

 
Français 

20 

 
Deutsch 

29 

Содержание ITE-XTRA

Страница 1: ...Europark Oost 24 Tel 32 3 766 02 02 E mail sales ite tools com 9100 Sint Niklaas Belgium Fax 32 3 766 10 67 1 ITE XTRA ...

Страница 2: ...formation 3 Features 3 Parts Controls 4 Getting started 4 Installing batteries 4 Operating features 5 Battery indicator 5 Automatic reset 6 Sensitivity adjustment 6 Alarm indications 7 Operating instructions 7 Operating tips 8 Applications 9 Maintenance 9 Replacement parts 10 Specifications 11 Warranty 11 Español 12 Français 20 Deutsch 29 ...

Страница 3: ...een added to enhance the usability of the ITE XTRA Seven levels of sensitivity provide an increase of 64 times from level 1 to level 7 Unique Tri color led s show a progressive and wide ranging leak size indications communicate the sensitivity level and provide a true voltage indication of battery power level A tactile keypad controls all functions of operation A revolutionary new case design give...

Страница 4: ...eference leak source Parts controls 1 Sensing tip 6 Audio mute 2 Tip protector 7 Sensitivity up 3 Power ON OFF 8 Sensitivity down 4 Battery test 9 LED leak indicators 5 Reset button 10 Flexible probe Getting started Installing batteries Remove the battery compartment door located on the bottom of the instrument by sliding up as shown below Install batteries positive polarity outwards towards batte...

Страница 5: ...on The constant power indicator allows the user to see the battery level at all times The LED will remain on whenever the unit is powered on It may appear as one of three colors See Fig 3 GREEN Battery voltage is normal sufficient for proper operation ORANGE Battery voltage is approaching the lower threshold for operation replace as soon as possible RED Battery voltage is below acceptable operatin...

Страница 6: ...unit automatically sets itself to ignore the level of refrigerant present at the tip Only a level or concentration greater than this will cause an alarm CAUTION Be aware that this feature will cause the unit to ignore any refrigerant present at turn on In other words with the unit off if you place the tip up to a known leak and switch the unit on no leak will be indicated RESET FEATURE Pressing th...

Страница 7: ...display will show the LED s red The number of LED s lit indicates the level See Fig 5 Level one lowest sensitivity is shown by the leftmost LED Counting from left levels 2 through 7 are indicated by the corresponding number of red LED s i e level 7 is shown by all LED s lit 2 Pressing the SENSITIVITY or SENSITIVITY key will change the sensitivity The keys can be pressed intermittently to change le...

Страница 8: ...e Orange one at a time Operating Instructions Operation 1 Switch the unit on by pressing the ON OFF key The display will illuminate with the reset indication Left LED green all others Orange for 2 seconds 2 Verify the battery level by observing the constant power indicator see above 3 Upon turn on the unit is set to sensitivity level 5 A rapid but steady beep rate will be heard If desired the sens...

Страница 9: ...32 3 766 02 02 E mail sales ite tools com 9100 Sint Niklaas Belgium Fax 32 3 766 10 67 9 6 If a full alarm occurs before the leak is pinpointed press the RESET key to reset the circuit to a zero reference as described above ...

Страница 10: ...mperatures below 15 C 59 F leaks may not be measurable since this pressure may not be reached 2 Take care not to contaminate the detector probe tip if the part being tested is contaminated If the part is particularly dirty or condensate moisture is present it should be wiped off with a dry shop towel or blown off with shop air No cleaners or solvents should be used since the detector may be sensit...

Страница 11: ... minimum shutting it off then waiting for the refrigerant to accumulate in the case for 10 minutes After such time insert the leak detector probe into the blower resistor block or condensate drain hole if no water is present or into the closest opening in the heating ventilation air conditioning case to the evaporator such as the heater duct or a vent duct If the detector alarms a leak apparently ...

Страница 12: ...tip protector Never use the unit without the protector in place Before using the unit always inspect the tip and protector to see that they are free of dirt and or grease To clean 1 Remove protector by grasping and pulling off tip 2 Clean protector with shop towel and or compressed air 3 If the tip itself is dirty it can be cleaned by immersing in a mild solvent such as alcohol for a few seconds a...

Страница 13: ...pped with one Carrying Case one Owner s Manual 2 C cell batteries and one replacement Sensing Tip and Protector To purchase replacement parts for your leak detector please contact your local distributor To ensure that you obtain the correct parts it is best to reference the part number when placing your order Replacement Parts ITE XTRA 2 Maintenance Kit 3 Sensing Tips 3 Tip Protectors ...

Страница 14: ...ured to provide unlimited service Should the unit be inoperative after performing the recommended maintenance a no charge repair or replacement will be made to the original purchaser if the claim is made within three years from the date of purchase This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use This warranty does not cover batte...