3.6.2.1 PH ALARM
ENT
ENT
Differential
Time
Reset
Stop
Change Units by pr/- and validate with ENT:
Differential: Value to add/ subtract from the Set Point, from which the Alarm is activated
Time: Time required for activating the Alarm
Reset: automatic Reset of the Alarm when the Reading returns to correct Values.
Y
: Reset activated
N
: There is no Reset. Press ESC to deactivate the Alarm
STOP
: in case of Alarm it stops the Control of:
T
: Total, stop all the dosing pumps
A
: Pumps in Channel A
B
: Pumps in Channel B
N
: Nothing
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
CAL
PROG
ALM
CONT
HIST
AUX
mS
m3h
3. CONFIGURATION
3.8.2. ALARMS
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
1
4
EC 31%
PH 86%
mS
m3h
EC+ 0.0 ----- s
EC - 0.0 ----- s
REARM: Y
STOP: T
ALM EC
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
CAL
PROG
ALM
CONT
HIST
AUX
mS
m3h
ALM
EC
PRES
Q
PH
3.8.2.2 EC ALARM
ENT
Differential
Time
Reactivation
Stop
Change Units by pr/- and validate by ENT.
Differential: Value to add/ subtract from the Set Point, from which the Alarm is activated
Time: Time required for activating the Alarm
Reset: automatic Reset of the Alarm when the Reading returns to correct Values.
Y
: Reset activated
N
: There is no Reset. Press ESC to deactivate the Alarm
STOP
: in case of Alarm it stops the Control of:
T
: Total, stop all the dosing pumps
A
: Pumps in Channel A
B
: Pumps in Channel B
N
: Nothing
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
CAL
PROG
ALM
CONT
HIST
AUX
mS
m3h
ALM
PH
PRES
Q
EC
ENT
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
1
4
EC 31%
PH 86%
mS
m3h
WATER CONTROLLER 3000
USER'S MANUAL
18