SAFETY OPERATIONAL GUIDANCE

In order to make sure the correct operation and safety using, please comply with

the following conditions when installation, operating and maintenance.

1) Make sure the connection of the ground wire is well enough when installation.

Do not use two-core plug. And make sure the input voltage of power supply is

as same as the one marked on the main controller.

2) Do not open the cover of the unit without permission especially the

high-voltage components marked with AC 100V to 240V, or there is risk of

shock.

3) Do not put the unit in extremely cold or hot place.

4) The unit will be heating when working. Please keep environment ventilation to

avoid overheating.

5) Please power off the unit in wet weather or not in use.

6) Please disconnect the AC power wiring from the AC power supply before the

below operations:

A. Remove or re-assembly any parts of the unit.

B. Disconnect or re-connect any plug of the unit or other connection

7) Non professionals without permission, please do not attempt to open the

enclosure,do not repair, in order to avoid the accident or exacerbation of

equipment damage degree.

8) Don't take any corrosive chemical powders or liquids spilled in the equipment or

in the vicinity of.

Содержание TS-0604M

Страница 1: ...Intelligently digital conference system User Manual TS 0604M Before using the system please read this manual first...

Страница 2: ...ameters change later another supply mentary instruction will be added the details can be inquired to the manufacturers This manual is a product manufacturer Copyright unauthorized and any entity or in...

Страница 3: ...here is risk of shock 3 Do not put the unit in extremely cold or hot place 4 The unit will be heating when working Please keep environment ventilation to avoid overheating 5 Please power off the unit...

Страница 4: ...voice distribution long distance telephone meeting voting and camera tracking system Always advocated the concept of a comprehensive system integration solutions which can do DCS digital conference sy...

Страница 5: ...inal sound channel output Speak limit function a unit quantity 1 2 4 6 adjustable chairman of the unit is not restricted Support FIFO NORMAL FREE APPLY a variety of conference model Support automatic...

Страница 6: ...man or the operator to speak P S chairman Not restricted by the above model 2 ACTIVE MICRO S A number of restrictions adjustable to the number of delegates unit at the same time open for 1 2 4 6 FREE...

Страница 7: ...e increase decrease Maximum volume OFF after the continue button is invalid 6 OFF Main volume mute lamp when the volume adjustment choose to OFF position the mute indicator light the main volume be tu...

Страница 8: ...roller or camera tracking controller automatic camera tracking function 5 DELEGATES Used to connect to conference unit each controller can connect to 128 unit maximum 6 ROUTE Extension socket connecti...

Страница 9: ...4 2 CONTROL SYSTEM COM foot position function description 3 PC COM foot position function description PC Foot position Signal Description 1 2 TXD Transmitter data 3 RXD Receive data 4 5 GND Signal ea...

Страница 10: ...ftware on the computer Click the conference control figure 1 enter the conference control interface the interface on the right side of the operation button can control the controller function figure 2...

Страница 11: ...ON When press the microphone button YES ON button the light is normally ON you can see the projection of the above data changed Click the end of a voting voting is completed 5 Priority Chairman unit...

Страница 12: ...9 Figure 2 Figure 3...

Страница 13: ...10 Figure 4 5 connection example...

Страница 14: ...W Maximum power 350W Output power 110W 24V every road Audio output Impedance 100 way nonequilibrium MIC input impedance 100k electronic level 60 dB way nonequilibrium Frequency response 60 16kHz Signa...

Отзывы: